Applying Nondestructive Ultrasonic Technique in the Metrological Control of Heat Treatment of AISI 1045 Steels

The characterization of mechanical properties in heat-treated carbon steels, which is crucial for quality control, traditionally relies on destructive testing. This study evaluated the reliability of the non-destructive ultrasonic technique as a metrological alternative for AISI 1045 steel. Samples subjected to six heat treatment conditions (Annealing, Normalizing, Quenching, and Tempering) were characterized by hardness, metallography, and ultrasound. Through linear regression analyses, the multiparametric model combining sound velocity, attenuation, and FWHM demonstrated exceptional metrological precision, resulting in a coefficient of determination of (R2 = 96.687%). The metrological robustness of the model was validated by quantifying the Expanded Uncertainty (U), following the GUM (Guide to the Expression of Uncertainty in Measurement). It is concluded that the multiparametric ultrasonic methodology is an accurate, robust, and non-destructive alternative for the quantitative determination of Vickers Hardness in AISI 1045 steels, contributing to the optimization of industrial processes and metrological rigor.

Authors

Institutions

Publication Details

Journal
Metrology
Published
2026-02-24
DOI
https://doi.org/10.3390/metrology6010015
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Applying Nondestructive Ultrasonic Technique in the Metrological Control of Heat Treatment of AISI 1045 Steels

Luciano Volcanoglo Biehl, José Carlos Bizerra Costa, Jorge Luis Braz Medeiros, Carlos Otávio Damas Martins
Metrology
Ultrasonics and Acoustic Wave Propagation
article

Applying Nondestructive Ultrasonic Technique in the Metrological Control of Heat Treatment of AISI 1045 Steels

Luciano Volcanoglo Biehl, José Carlos Bizerra Costa, Jorge Luis Braz Medeiros, Carlos Otávio Damas Martins
article en

Abstract

The characterization of mechanical properties in heat-treated carbon steels, which is crucial for quality control, traditionally relies on destructive testing. This study evaluated the reliability of the non-destructive ultrasonic technique as a metrological alternative for AISI 1045 steel. Samples subjected to six heat treatment conditions (Annealing, Normalizing, Quenching, and Tempering) were characterized by hardness, metallography, and ultrasound. Through linear regression analyses, the multiparametric model combining sound velocity, attenuation, and FWHM demonstrated exceptional metrological precision, resulting in a coefficient of determination of (R2 = 96.687%). The metrological robustness of the model was validated by quantifying the Expanded Uncertainty (U), following the GUM (Guide to the Expression of Uncertainty in Measurement). It is concluded that the multiparametric ultrasonic methodology is an accurate, robust, and non-destructive alternative for the quantitative determination of Vickers Hardness in AISI 1045 steels, contributing to the optimization of industrial processes and metrological rigor.

MetrologyVol. 6(1)
Universidade Federal do Rio Grande (BR), Universidade Federal de Sergipe (BR), University of Rio Grande and Rio Grande Community College (US)
Openalex Percentile: Top 45%
Ultrasonics and Acoustic Wave Propagation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.