Correlation between insertion torque value and bone density in D3 and D4 bone following photobiomodulation: a randomised interventional study

This study aimed to assess the correlation between insertion torque values and bone density measured via CBCT in D3 and D4 bone types after photobiomodulation (PBM) therapy. 108 partially edentulous patients were divided into six groups based on PBM therapy type and bone classification. Insertion torque values were recorded during implant placement, and bone density was assessed via CBCT. Statistically significant positive correlations were observed between bone density and insertion torque in all regions (cervical, middle, apical) for both D3 and D4 bone types (Spearman’s rho ≥ 0.951, p < 0.01). Bone density correlates strongly with insertion torque values in both D3 and D4 bone following PBM therapy, suggesting its potential predictive value for implant primary stability. With the findings of the study, CBCT can be used as a predictive tool for assessing the implant stability and also advocates the use of PBM as an adjunct to improve primary implant stability. CTRI/2022/04/042033 dated 8/02/2022.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-02-24
DOI
https://doi.org/10.1186/s12903-026-07875-w
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation between insertion torque value and bone density in D3 and D4 bone following photobiomodulation: a randomised interventional study

Sheetal R Khubchandani, S. R. Godbole, Ashika Singhania, Sharayu V. Nimonkar et al.
BMC Oral Health
Laser Applications in Dentistry and Medicine
article

Correlation between insertion torque value and bone density in D3 and D4 bone following photobiomodulation: a randomised interventional study

Sheetal R Khubchandani, S. R. Godbole, Ashika Singhania, Sharayu V. Nimonkar, Anjali Borle
article en

Abstract

This study aimed to assess the correlation between insertion torque values and bone density measured via CBCT in D3 and D4 bone types after photobiomodulation (PBM) therapy. 108 partially edentulous patients were divided into six groups based on PBM therapy type and bone classification. Insertion torque values were recorded during implant placement, and bone density was assessed via CBCT. Statistically significant positive correlations were observed between bone density and insertion torque in all regions (cervical, middle, apical) for both D3 and D4 bone types (Spearman’s rho ≥ 0.951, p < 0.01). Bone density correlates strongly with insertion torque values in both D3 and D4 bone following PBM therapy, suggesting its potential predictive value for implant primary stability. With the findings of the study, CBCT can be used as a predictive tool for assessing the implant stability and also advocates the use of PBM as an adjunct to improve primary implant stability. CTRI/2022/04/042033 dated 8/02/2022.

BMC Oral Health
Datta Meghe Institute of Higher Education and Research (IN)
Openalex Percentile: Top 46%
Laser Applications in Dentistry and Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.