Reproducibility of Echocardiographic Measurements of Right Ventricular Function: Comparison Between TAPSE and TDI S′

(1) Background: Assessment of right ventricular (RV) function has become increasingly important in echocardiography due to its prognostic significance in cardiac and systemic diseases. (2) Objectives: Tricuspid Annular Plane Systolic Excursion (TAPSE) and Tissue Doppler Imaging (TDI S') are commonly used methods to assess RV function. The aim of this study was to compare the reproducibility of TAPSE and TDI S' among experienced operators. (3) Methods: A study was conducted on 100 consecutive patients with systemic sclerosis undergoing echocardiography evaluation screening for pulmonary hypertension. Standardized echocardiography images were acquired using a Philips EPIQ system (Philips Healthcare, Amsterdam, The Netherlands), measuring TAPSE and TDI S'. Five operators independently analyzed the images, with each blinded to the results. Exclusion criteria included pathological TAPSE or TDI S' values, as well as indirect echocardiography signs of pulmonary hypertension. (4) Results: The study's results indicate that there was superior inter-operator agreement for TDI S' (ICC = 0.891) compared to TAPSE (ICC = 0.47). The mean TAPSE measurements ranged from 23.49 mm to 23.99 mm, while TDI S' values ranged from 12.16 cm/s to 12.35 cm/s, with TDI S' showing narrower confidence intervals. (5) Conclusions: Echocardiographic assessment of right ventricular (RV) function is crucial in clinical practice. Tissue Doppler imaging-derived systolic velocity (TDI S') demonstrated superior reproducibility compared to tricuspid annular plane systolic excursion (TAPSE) in evaluating RV function. This enhanced reproducibility supports the routine incorporation of TDI S' as a highly reproducible parameter within a multiparametric assessment framework.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Development and Disease
Published
2026-02-24
DOI
https://doi.org/10.3390/jcdd13030104
Primary Topic
Pulmonary Hypertension Research and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducibility of Echocardiographic Measurements of Right Ventricular Function: Comparison Between TAPSE and TDI S′

Anna Vittoria Mattioli, D. Aschieri, Amelia Spinella, Gilda Sandri et al.
Journal of Cardiovascular Development and Disease
Pulmonary Hypertension Research and Treatments
article

Reproducibility of Echocardiographic Measurements of Right Ventricular Function: Comparison Between TAPSE and TDI S′

Anna Vittoria Mattioli, D. Aschieri, Amelia Spinella, Gilda Sandri, Marcello Pinti, Marco de Pinto, F Fedele, Arianna Maini, Alessio Baccarani, Francesca Coppi, Dilia Giuggioli, Gianluca Pagnoni, Susan Darroudi
article en

Abstract

(1) Background: Assessment of right ventricular (RV) function has become increasingly important in echocardiography due to its prognostic significance in cardiac and systemic diseases. (2) Objectives: Tricuspid Annular Plane Systolic Excursion (TAPSE) and Tissue Doppler Imaging (TDI S') are commonly used methods to assess RV function. The aim of this study was to compare the reproducibility of TAPSE and TDI S' among experienced operators. (3) Methods: A study was conducted on 100 consecutive patients with systemic sclerosis undergoing echocardiography evaluation screening for pulmonary hypertension. Standardized echocardiography images were acquired using a Philips EPIQ system (Philips Healthcare, Amsterdam, The Netherlands), measuring TAPSE and TDI S'. Five operators independently analyzed the images, with each blinded to the results. Exclusion criteria included pathological TAPSE or TDI S' values, as well as indirect echocardiography signs of pulmonary hypertension. (4) Results: The study's results indicate that there was superior inter-operator agreement for TDI S' (ICC = 0.891) compared to TAPSE (ICC = 0.47). The mean TAPSE measurements ranged from 23.49 mm to 23.99 mm, while TDI S' values ranged from 12.16 cm/s to 12.35 cm/s, with TDI S' showing narrower confidence intervals. (5) Conclusions: Echocardiographic assessment of right ventricular (RV) function is crucial in clinical practice. Tissue Doppler imaging-derived systolic velocity (TDI S') demonstrated superior reproducibility compared to tricuspid annular plane systolic excursion (TAPSE) in evaluating RV function. This enhanced reproducibility supports the routine incorporation of TDI S' as a highly reproducible parameter within a multiparametric assessment framework.

Journal of Cardiovascular Development and DiseaseVol. 13(3)
University of Modena and Reggio Emilia (IT), Azienda Ospedaliero-Universitaria di Modena (IT), Guglielmo da Saliceto Hospital (IT), Sapienza University of Rome (IT), University of Bologna (IT)
European Commission
Reduced inequalities
Openalex Percentile: Top 45%
Pulmonary Hypertension Research and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.