A High-Precision Time-Varying Survival Model for Early Prediction of Patient Deterioration: A Retrospective Cohort Study

<b>Background:</b> Clinicians rely on clinical judgement and vital sign monitoring to identify patient deterioration, commonly supported by systems such as the National Early Warning Score 2 (NEWS2). However, NEWS2 is associated with a high false-positive burden, contributing to alert fatigue in increasingly pressured clinical environments. Consequently, there is a growing need for early warning systems (EWS) that not only detect deterioration but do so with higher precision to prioritise clinically meaningful alerts. We aimed to develop and validate a prognostic EWS capable of predicting real-time clinical deterioration in hospitalised adult patients. <b>Methods:</b> We conducted a retrospective observational cohort study using routinely collected Electronic Patient Record (EPR) data. A Cox proportional hazards model with time-varying covariates was developed to estimate dynamic risk of deterioration. Deterioration was defined as unplanned transfer to intensive care, unplanned surgery, or in-hospital death. Data for model development comprised 37,989 adult inpatient episodes admitted between January 2022 and October 2024, and were initially split into training, temporal validation and test datasets. An extended evaluation period included 11,048 patients admitted through September 2025. Model performance was compared with NEWS2 at the emergency-response threshold (≥7). <b>Results:</b> The final model produced a tiered "traffic-light" risk profile and demonstrated substantially higher precision than NEWS2 while maintaining comparable recall in our test data. At the red alert threshold, precision was 60% compared with 16% for NEWS2 ≥7, with 82% versus 43% of alerts occurring within 24 h of deterioration. Performance remained consistent across the extended evaluation period. <b>Conclusions:</b> A survival-based EWS incorporating time-varying covariates achieved higher precision and improved temporal alignment with deterioration events compared with NEWS2. A tiered amber-red alert framework may support more targeted escalation, reduce alert fatigue, and enhance early identification of clinical deterioration.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-02-24
DOI
https://doi.org/10.3390/jcm15051690
Primary Topic
Sepsis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High-Precision Time-Varying Survival Model for Early Prediction of Patient Deterioration: A Retrospective Cohort Study

Brian Wood, Martin Farrier, Nishchay Joshi, Thomas Ingram
Journal of Clinical Medicine
Sepsis Diagnosis and Treatment
article

A High-Precision Time-Varying Survival Model for Early Prediction of Patient Deterioration: A Retrospective Cohort Study

Brian Wood, Martin Farrier, Nishchay Joshi, Thomas Ingram
article en

Abstract

<b>Background:</b> Clinicians rely on clinical judgement and vital sign monitoring to identify patient deterioration, commonly supported by systems such as the National Early Warning Score 2 (NEWS2). However, NEWS2 is associated with a high false-positive burden, contributing to alert fatigue in increasingly pressured clinical environments. Consequently, there is a growing need for early warning systems (EWS) that not only detect deterioration but do so with higher precision to prioritise clinically meaningful alerts. We aimed to develop and validate a prognostic EWS capable of predicting real-time clinical deterioration in hospitalised adult patients. <b>Methods:</b> We conducted a retrospective observational cohort study using routinely collected Electronic Patient Record (EPR) data. A Cox proportional hazards model with time-varying covariates was developed to estimate dynamic risk of deterioration. Deterioration was defined as unplanned transfer to intensive care, unplanned surgery, or in-hospital death. Data for model development comprised 37,989 adult inpatient episodes admitted between January 2022 and October 2024, and were initially split into training, temporal validation and test datasets. An extended evaluation period included 11,048 patients admitted through September 2025. Model performance was compared with NEWS2 at the emergency-response threshold (≥7). <b>Results:</b> The final model produced a tiered "traffic-light" risk profile and demonstrated substantially higher precision than NEWS2 while maintaining comparable recall in our test data. At the red alert threshold, precision was 60% compared with 16% for NEWS2 ≥7, with 82% versus 43% of alerts occurring within 24 h of deterioration. Performance remained consistent across the extended evaluation period. <b>Conclusions:</b> A survival-based EWS incorporating time-varying covariates achieved higher precision and improved temporal alignment with deterioration events compared with NEWS2. A tiered amber-red alert framework may support more targeted escalation, reduce alert fatigue, and enhance early identification of clinical deterioration.

Journal of Clinical MedicineVol. 15(5)
Wrightington, Wigan and Leigh NHS Foundation Trust (GB)
Openalex Percentile: Top 45%
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.