Limb occlusion pressure adjusted tourniquet use results in adequate hemostasis in pediatric limb surgeries: a prospective clinical study

Tourniquets are widely used in pediatric orthopedic surgeries to provide a bloodless operative field. However, inappropriate application can lead to complications. This study evaluates the efficacy and safety of using Doppler-derived limb occlusion pressure (LOP) to guide tourniquet pressure in children. A prospective observational study was conducted from November 2022 to February 2025 in a tertiary care orthopedic department. Pediatric patients (age: 1–15 years) undergoing upper or lower limb surgery were included. Tourniquet pressure was set at LOP + 50 mmHg, measured using a handheld Doppler. The primary outcome was adequacy of hemostasis; tourniquet-related complications were also recorded. The study included 122 patients (135 limbs), with a mean age of 8 years. Mean LOP was 111.4 ± 18.8 mmHg; mean tourniquet pressure was 161.7 ± 19.3 mmHg. Adequate hemostasis (Likert scale ≥ 3) was achieved in 95.55% of procedures. A strong linear correlation was observed between systolic blood pressure and tourniquet pressure [tourniquet pressure = (0.90 × systolic blood pressure) + 77 mmHg; P < 0.001]. No tourniquet-related complications were observed. LOP-guided tourniquet application is safe and effective in pediatric limb surgeries, allowing significant reduction in pressure compared to adult population.

Authors

Institutions

Publication Details

Journal
Journal of Pediatric Orthopaedics B
Published
2026-02-25
DOI
https://doi.org/10.1097/bpb.0000000000001339
Primary Topic
Blood transfusion and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Limb occlusion pressure adjusted tourniquet use results in adequate hemostasis in pediatric limb surgeries: a prospective clinical study

Lokesh Raghav, Seema Gupta, Nitesh Kumar, Pranay Kalia et al.
Journal of Pediatric Orthopaedics B
Blood transfusion and management
article

Limb occlusion pressure adjusted tourniquet use results in adequate hemostasis in pediatric limb surgeries: a prospective clinical study

Lokesh Raghav, Seema Gupta, Nitesh Kumar, Pranay Kalia, Yogesh Kumar, Shray Jain
article en

Abstract

Tourniquets are widely used in pediatric orthopedic surgeries to provide a bloodless operative field. However, inappropriate application can lead to complications. This study evaluates the efficacy and safety of using Doppler-derived limb occlusion pressure (LOP) to guide tourniquet pressure in children. A prospective observational study was conducted from November 2022 to February 2025 in a tertiary care orthopedic department. Pediatric patients (age: 1–15 years) undergoing upper or lower limb surgery were included. Tourniquet pressure was set at LOP + 50 mmHg, measured using a handheld Doppler. The primary outcome was adequacy of hemostasis; tourniquet-related complications were also recorded. The study included 122 patients (135 limbs), with a mean age of 8 years. Mean LOP was 111.4 ± 18.8 mmHg; mean tourniquet pressure was 161.7 ± 19.3 mmHg. Adequate hemostasis (Likert scale ≥ 3) was achieved in 95.55% of procedures. A strong linear correlation was observed between systolic blood pressure and tourniquet pressure [tourniquet pressure = (0.90 × systolic blood pressure) + 77 mmHg; P < 0.001]. No tourniquet-related complications were observed. LOP-guided tourniquet application is safe and effective in pediatric limb surgeries, allowing significant reduction in pressure compared to adult population.

Journal of Pediatric Orthopaedics BVol. 35(3)
Lady Hardinge Medical College (IN)
Good health and well-being
Openalex Percentile: Top 47%
Blood transfusion and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.