CO2 Sensing Using Symmetrical Three-Wavelength Precompensated Current-Modulated Tunable Diode Laser Absorption Spectroscopy

In this paper, a novel symmetrical three-wavelength toggling archetype for measuring the concentration of gases using a tunable diode laser absorption spectroscopy (TDLAS) system is introduced and demonstrated. The system was operated at 1.5714 µm with a 2 kHz update rate, targeting an absorption line of gaseous CO<sub>2</sub>. Precompensated diode-current pulses are introduced to offset the inherent thermal time constants of the diode laser by orders of magnitude. Here, repetition rates matching that of contemporary methods can be achieved, while simultaneously providing a noteworthy wavelength stability of 0.6 pm for the three targeted wavelengths that are approximately 70 pm apart (142 pm maximum wavelength excursion). A 10 Hz current loop locks one of the wavelengths to a CO<sub>2</sub> absorption peak, thus providing an absolute and stable wavelength reference. The flexibility in choosing the shape and repetition frequency of the current pulses makes this approach easily adaptable to other gases and/or absorption lines, since wavelength filters are avoided. The new method is benchmarked against a two-wavelength precompensated continuous-wave TDLAS technique, revealing a fourfold improvement in reproducibility with system restart over the span of 24 days, while outperforming other widespread spectroscopic techniques applied to comparable transmittance levels. The effect of the analytical model was further studied by thermally inducing baseline changes, showing a 7.9 ± 0.2 times weaker correlation between concentration and temperature with respect to the one observed using the two-wavelength TDLAS archetype. These results demonstrate the system's suitability for sensitive applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-24
DOI
https://doi.org/10.3390/s26051420
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CO2 Sensing Using Symmetrical Three-Wavelength Precompensated Current-Modulated Tunable Diode Laser Absorption Spectroscopy

Giacomo Zanetti, Peter John Rodrigo, Christian Pedersen
Sensors
Spectroscopy and Laser Applications
article

CO2 Sensing Using Symmetrical Three-Wavelength Precompensated Current-Modulated Tunable Diode Laser Absorption Spectroscopy

Giacomo Zanetti, Peter John Rodrigo, Christian Pedersen
article en

Abstract

In this paper, a novel symmetrical three-wavelength toggling archetype for measuring the concentration of gases using a tunable diode laser absorption spectroscopy (TDLAS) system is introduced and demonstrated. The system was operated at 1.5714 µm with a 2 kHz update rate, targeting an absorption line of gaseous CO<sub>2</sub>. Precompensated diode-current pulses are introduced to offset the inherent thermal time constants of the diode laser by orders of magnitude. Here, repetition rates matching that of contemporary methods can be achieved, while simultaneously providing a noteworthy wavelength stability of 0.6 pm for the three targeted wavelengths that are approximately 70 pm apart (142 pm maximum wavelength excursion). A 10 Hz current loop locks one of the wavelengths to a CO<sub>2</sub> absorption peak, thus providing an absolute and stable wavelength reference. The flexibility in choosing the shape and repetition frequency of the current pulses makes this approach easily adaptable to other gases and/or absorption lines, since wavelength filters are avoided. The new method is benchmarked against a two-wavelength precompensated continuous-wave TDLAS technique, revealing a fourfold improvement in reproducibility with system restart over the span of 24 days, while outperforming other widespread spectroscopic techniques applied to comparable transmittance levels. The effect of the analytical model was further studied by thermally inducing baseline changes, showing a 7.9 ± 0.2 times weaker correlation between concentration and temperature with respect to the one observed using the two-wavelength TDLAS archetype. These results demonstrate the system's suitability for sensitive applications.

SensorsVol. 26(5)
Technical University of Denmark (DK)
Affordable and clean energy
Openalex Percentile: Top 47%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.