Effect of Printing Orientation on the Dimensional Accuracy of 3D-Printed Denture Base

Additive manufacturing is now an integral part of digital prosthodontic workflows, and although stereolithography (SLA) is widely used for denture base fabrication, the dimensional accuracy of printed dentures remains highly dependent on manufacturing parameters, particularly build orientation. This study evaluated the influence of build orientation on the trueness and precision of SLA-printed maxillary and mandibular denture bases. Thirty complete denture bases were fabricated using SLA and divided into three groups according to build orientation: 0°, 45°, and 90° (<i>n</i> = 10). The intaglio surfaces of the printed dentures were scanned and compared with their corresponding digital reference models using three-dimensional inspection software. Trueness was quantified using root mean square error (<i>RMSE</i>) and directional deviations, while precision was assessed based on the variability of <i>RMSE</i> values within each group. Statistical analysis was performed using one-way ANOVA and Tukey's post hoc test (<i>p</i> ≤ 0.05). Build orientation significantly affected the trueness of maxillary denture bases, with dentures printed at 90° demonstrating the lowest <i>RMSE</i> values. No statistically significant differences in trueness were observed among build orientations for mandibular denture bases. Precision was not influenced by build orientation for maxillary dentures, whereas mandibular dentures printed at 90° exhibited significantly greater variability compared with 0° and 45°. Build orientation is a critical factor influencing the dimensional accuracy of SLA-printed denture bases in an arch-dependent manner. Optimizing build orientation may enhance both accuracy and reproducibility, thereby improving the predictability and clinical reliability of additively manufactured denture bases.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-02-24
DOI
https://doi.org/10.3390/jfb17030109
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Printing Orientation on the Dimensional Accuracy of 3D-Printed Denture Base

Todor Ts. Uzunov, Dimitar Kirov, Todor Bogdanov, Todorov Rg et al.
Journal of Functional Biomaterials
Dental materials and restorations
article

Effect of Printing Orientation on the Dimensional Accuracy of 3D-Printed Denture Base

Todor Ts. Uzunov, Dimitar Kirov, Todor Bogdanov, Todorov Rg, Ivet Dzhondrova, Nickolay Apostolov, Ilia Liondev
article en

Abstract

Additive manufacturing is now an integral part of digital prosthodontic workflows, and although stereolithography (SLA) is widely used for denture base fabrication, the dimensional accuracy of printed dentures remains highly dependent on manufacturing parameters, particularly build orientation. This study evaluated the influence of build orientation on the trueness and precision of SLA-printed maxillary and mandibular denture bases. Thirty complete denture bases were fabricated using SLA and divided into three groups according to build orientation: 0°, 45°, and 90° (<i>n</i> = 10). The intaglio surfaces of the printed dentures were scanned and compared with their corresponding digital reference models using three-dimensional inspection software. Trueness was quantified using root mean square error (<i>RMSE</i>) and directional deviations, while precision was assessed based on the variability of <i>RMSE</i> values within each group. Statistical analysis was performed using one-way ANOVA and Tukey's post hoc test (<i>p</i> ≤ 0.05). Build orientation significantly affected the trueness of maxillary denture bases, with dentures printed at 90° demonstrating the lowest <i>RMSE</i> values. No statistically significant differences in trueness were observed among build orientations for mandibular denture bases. Precision was not influenced by build orientation for maxillary dentures, whereas mandibular dentures printed at 90° exhibited significantly greater variability compared with 0° and 45°. Build orientation is a critical factor influencing the dimensional accuracy of SLA-printed denture bases in an arch-dependent manner. Optimizing build orientation may enhance both accuracy and reproducibility, thereby improving the predictability and clinical reliability of additively manufactured denture bases.

Journal of Functional BiomaterialsVol. 17(3)
Medical University of Sofia (BG)
Openalex Percentile: Top 46%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.