Establishment of standardized intraoral implant model in the rabbit edentulous diastema

• The edentulous diastema 7.50-10.50 mm mesial to the mandibular first premolar is an optimal intraoral implant site in rabbits. • The standardized workflow provides a highly reproducible, economical, and effective intraoral implant model for the osseointegration research. • The standardized rabbit intraoral implant model has utility for modeling the peri-implant mucositis and peri-implantitis. Rabbits have been valued for decades as a model for osseointegration research and biomaterial evaluation, owing to the practical handling, ethical acceptance, and cost-effectiveness. The rabbit model provides an optimal compromise between clinical translatability and practical experimental viability when compared to both large-animal and rodent alternatives. However, rabbit models face inconsistencies across implant site selection criteria, implant geometric configurations, and operative techniques, underscoring the urgent need for standardized experimental frameworks to improve cross-study comparability. The edentulous diastema in rabbit mandible—an anatomical edentulous zone between incisors and premolars—is recognized as a promising intraoral site for implant placement due to its enhanced trabecular bone density and superior volumetric capacity. In contrast to commonly used extragnathic sites (e.g., tibia, femur), which lack a relevant oral microenvironment, the mandibular diastema offers both close anatomical analogy to the human jaw and straightforward surgical access. Herein, we identified an anatomically optimal implant site in rabbit mandibular edentulous diastema utilizing micro-CT-based quantitative analyses and designed a customized implant according to the measured value. Subsequently, we developed a standardized operative workflow for implant placement, and evaluated the osseointegration following 4 weeks and 12 weeks of implantation. Furthermore, we confirmed the applicability of the standardized rabbit intraoral implant model for peri-implantitis modeling. Collectively, we established a workflow for standardizing an intraoral implant model in the edentulous diastema of rabbits which provide highly reproducible, economical, and effective platform for fundamental inquiries into osseointegration, the evaluation of novel implant surface coatings, and the initial screening of biomaterials.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2026-02-25
DOI
https://doi.org/10.1016/j.rineng.2026.109755
Primary Topic
Reconstructive Facial Surgery Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment of standardized intraoral implant model in the rabbit edentulous diastema

Yan Li, Zhiqian Ye, Shuyi Wu, Xinning Dai et al.
Results in Engineering
Reconstructive Facial Surgery Techniques
article

Establishment of standardized intraoral implant model in the rabbit edentulous diastema

Yan Li, Zhiqian Ye, Shuyi Wu, Xinning Dai, Shujin Li, Weiran Li, Xiaoqiong Huang, Xinwen Deng, Zixiang Liu
article en

Abstract

• The edentulous diastema 7.50-10.50 mm mesial to the mandibular first premolar is an optimal intraoral implant site in rabbits. • The standardized workflow provides a highly reproducible, economical, and effective intraoral implant model for the osseointegration research. • The standardized rabbit intraoral implant model has utility for modeling the peri-implant mucositis and peri-implantitis. Rabbits have been valued for decades as a model for osseointegration research and biomaterial evaluation, owing to the practical handling, ethical acceptance, and cost-effectiveness. The rabbit model provides an optimal compromise between clinical translatability and practical experimental viability when compared to both large-animal and rodent alternatives. However, rabbit models face inconsistencies across implant site selection criteria, implant geometric configurations, and operative techniques, underscoring the urgent need for standardized experimental frameworks to improve cross-study comparability. The edentulous diastema in rabbit mandible—an anatomical edentulous zone between incisors and premolars—is recognized as a promising intraoral site for implant placement due to its enhanced trabecular bone density and superior volumetric capacity. In contrast to commonly used extragnathic sites (e.g., tibia, femur), which lack a relevant oral microenvironment, the mandibular diastema offers both close anatomical analogy to the human jaw and straightforward surgical access. Herein, we identified an anatomically optimal implant site in rabbit mandibular edentulous diastema utilizing micro-CT-based quantitative analyses and designed a customized implant according to the measured value. Subsequently, we developed a standardized operative workflow for implant placement, and evaluated the osseointegration following 4 weeks and 12 weeks of implantation. Furthermore, we confirmed the applicability of the standardized rabbit intraoral implant model for peri-implantitis modeling. Collectively, we established a workflow for standardizing an intraoral implant model in the edentulous diastema of rabbits which provide highly reproducible, economical, and effective platform for fundamental inquiries into osseointegration, the evaluation of novel implant surface coatings, and the initial screening of biomaterials.

Results in EngineeringVol. 30
Yonsei University (KR), Stomatology Hospital (CN)
Zero hunger
Openalex Percentile: Top 46%
Reconstructive Facial Surgery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.