Geometric Fidelity of Magnetic Resonance Imaging and Computed Tomography-Derived Virtual 3D Models of Porcine Cadaver Mandibles: Conventional Versus Artificial Intelligence-Based Segmentation.

Purpose The workflow for virtual surgical planning (VSP) and the application of CAD/CAM (computer-aided design/computer-aided manufacturing) procedures are mainly based on computed tomography (CT) derived DICOM data sets. Alternatively, this study aims to preclinically illuminate the feasibility of a magnetic resonance imaging (MRI) based workflow and the impact of artificial intelligence (AI) based segmentation on the required fidelity on basic 3D geometry acquisition.Materials And Methods Porcine cadaver mandibles were imaged with CT and a T1-weighted MRI sequence. The resulting DICOM data sets were segmented conventionally (Mimics Medical 17.0, Materialize; Belgium) and with AI-based segmentation software (ImFusion Labels and Suite, Version 2.19.2, ImFusion; Germany). The four standard tessellation language (STL) files were superimposed with a corresponding reference model derived from an optic scan (Artec Space Spider, Artec 3D; Luxembourg) and the following parameters were analysed: Hausdorff distance (HD), mean surface distance (MSD), root mean square distance (RMSD), time.Results In comparison to the reference model, all four parameters were significantly (P 0.001) better for the CT imaging and the AI-based segmentation. MRI-derived AI-based segmentation reached the fidelity of CT imaging data sets and conventional segmentation (HD, MSD, and RMSD each P >0.05).Conclusion The use of AI-based segmentation software proved to be useful and feasible for MRI-derived data sets, and generated the desired 3D geometry more quickly while maintaining the necessary quality. Nevertheless, the results for the CT were still better and remain yet the standard.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-11-26
DOI
https://doi.org/10.48620/93258
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geometric Fidelity of Magnetic Resonance Imaging and Computed Tomography-Derived Virtual 3D Models of Porcine Cadaver Mandibles: Conventional Versus Artificial Intelligence-Based Segmentation.

Probst Monika, Mathias Herrmann, Florian Probst, Herbert Deppe et al.
Open Access CRIS of the University of Bern
Dental Radiography and Imaging
article

Geometric Fidelity of Magnetic Resonance Imaging and Computed Tomography-Derived Virtual 3D Models of Porcine Cadaver Mandibles: Conventional Versus Artificial Intelligence-Based Segmentation.

Probst Monika, Mathias Herrmann, Florian Probst, Herbert Deppe, Katharina Pippich, Lucas M Ritschl, Anton Sculean
article en

Abstract

Purpose The workflow for virtual surgical planning (VSP) and the application of CAD/CAM (computer-aided design/computer-aided manufacturing) procedures are mainly based on computed tomography (CT) derived DICOM data sets. Alternatively, this study aims to preclinically illuminate the feasibility of a magnetic resonance imaging (MRI) based workflow and the impact of artificial intelligence (AI) based segmentation on the required fidelity on basic 3D geometry acquisition.Materials And Methods Porcine cadaver mandibles were imaged with CT and a T1-weighted MRI sequence. The resulting DICOM data sets were segmented conventionally (Mimics Medical 17.0, Materialize; Belgium) and with AI-based segmentation software (ImFusion Labels and Suite, Version 2.19.2, ImFusion; Germany). The four standard tessellation language (STL) files were superimposed with a corresponding reference model derived from an optic scan (Artec Space Spider, Artec 3D; Luxembourg) and the following parameters were analysed: Hausdorff distance (HD), mean surface distance (MSD), root mean square distance (RMSD), time.Results In comparison to the reference model, all four parameters were significantly (P 0.001) better for the CT imaging and the AI-based segmentation. MRI-derived AI-based segmentation reached the fidelity of CT imaging data sets and conventional segmentation (HD, MSD, and RMSD each P >0.05).Conclusion The use of AI-based segmentation software proved to be useful and feasible for MRI-derived data sets, and generated the desired 3D geometry more quickly while maintaining the necessary quality. Nevertheless, the results for the CT were still better and remain yet the standard.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Openalex Percentile: Top 23%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.