Diagnostic Accuracy of Raman Spectroscopy for Oral Potentially Malignant Disorders: A Systematic Review and Meta-Analysis

<b>Objective</b>: The aim of this study was to summarize the accuracy and efficacy of Raman spectroscopy (RS) technology in identifying Oral Potentially Malignant Disorders (OPMDs). <b>Methods</b>: This systematic review was registered in PROSPERO (CRD420251124866). A literature search was conducted in databases including PubMed, Embase, and Web of Science from inception up to September 2025. The risk of bias of included studies was evaluated using the QUADAS-2 tool. Appropriate statistical techniques were applied to perform heterogeneity analysis, subgroup analyses, and calculation of pooled diagnostic efficacy indices. <b>Results</b>: A total of 12 studies involving 2810 samples were included. In the "OPMDs vs. Normal" group, RS achieved a pooled sensitivity of 0.84 (95% CI: 0.78-0.88), specificity of 0.90 (95% CI: 0.73-0.97), and AUC of 0.89 (95% CI: 0.86-0.91). In the "OPMDs vs. Oral squamous cell carcinoma (OSCC)" group, the pooled sensitivity was 0.89 (95% CI: 0.82-0.94), specificity was 0.91 (95% CI: 0.85-0.95), and AUC was 0.94 (95% CI: 0.91-0.96). Heterogeneity analysis revealed low heterogeneity in the "OPMDs vs. OSCC" group (I<sup>2</sup> = 22.8%) and moderate heterogeneity in the "OPMDs vs. Normal oral mucosa" group (I<sup>2</sup> = 58.9%). Subgroup analyses were performed: sample type exerted no significant impact on heterogeneity (<i>p</i> > 0.19), while Raman type (micro vs. fiber) showed potential to modulate diagnostic efficacy, micro-Raman had higher sensitivity (0.916 vs. 0.811), and fiber-Raman had better specificity (0.917 vs. 0.843). No significant publication bias was observed (Egger's <i>p</i> > 0.3). <b>Conclusions</b>: Raman spectroscopy is an effective and reliable tool for screening and differentiating OPMDs.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-02-24
DOI
https://doi.org/10.3390/diagnostics16050648
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Accuracy of Raman Spectroscopy for Oral Potentially Malignant Disorders: A Systematic Review and Meta-Analysis

Xing Li, Qing Sun, Xiting Xiang, Nuo Hu et al.
Diagnostics
Spectroscopy Techniques in Biomedical and Chemical Research
article

Diagnostic Accuracy of Raman Spectroscopy for Oral Potentially Malignant Disorders: A Systematic Review and Meta-Analysis

Xing Li, Qing Sun, Xiting Xiang, Nuo Hu, Tao Zhang, Zhihui Zhu
article en

Abstract

<b>Objective</b>: The aim of this study was to summarize the accuracy and efficacy of Raman spectroscopy (RS) technology in identifying Oral Potentially Malignant Disorders (OPMDs). <b>Methods</b>: This systematic review was registered in PROSPERO (CRD420251124866). A literature search was conducted in databases including PubMed, Embase, and Web of Science from inception up to September 2025. The risk of bias of included studies was evaluated using the QUADAS-2 tool. Appropriate statistical techniques were applied to perform heterogeneity analysis, subgroup analyses, and calculation of pooled diagnostic efficacy indices. <b>Results</b>: A total of 12 studies involving 2810 samples were included. In the "OPMDs vs. Normal" group, RS achieved a pooled sensitivity of 0.84 (95% CI: 0.78-0.88), specificity of 0.90 (95% CI: 0.73-0.97), and AUC of 0.89 (95% CI: 0.86-0.91). In the "OPMDs vs. Oral squamous cell carcinoma (OSCC)" group, the pooled sensitivity was 0.89 (95% CI: 0.82-0.94), specificity was 0.91 (95% CI: 0.85-0.95), and AUC was 0.94 (95% CI: 0.91-0.96). Heterogeneity analysis revealed low heterogeneity in the "OPMDs vs. OSCC" group (I<sup>2</sup> = 22.8%) and moderate heterogeneity in the "OPMDs vs. Normal oral mucosa" group (I<sup>2</sup> = 58.9%). Subgroup analyses were performed: sample type exerted no significant impact on heterogeneity (<i>p</i> > 0.19), while Raman type (micro vs. fiber) showed potential to modulate diagnostic efficacy, micro-Raman had higher sensitivity (0.916 vs. 0.811), and fiber-Raman had better specificity (0.917 vs. 0.843). No significant publication bias was observed (Egger's <i>p</i> > 0.3). <b>Conclusions</b>: Raman spectroscopy is an effective and reliable tool for screening and differentiating OPMDs.

DiagnosticsVol. 16(5)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN)
Openalex Percentile: Top 49%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.