Numerical investigation of PCM-integrated emergency tents for energy-efficient thermal management in hot desert climates

• Numerical study of PCM-integrated tents for energy-efficient cooling in deserts. • CFD-based transient model addressing thermal comfort in emergency shelters. • PCM reduces indoor air stratification, lowering gradients by up to 5.4 K. • Roof PCM reaches full melting (LF ≈ 1.0) during peak solar hours. • PCM-integrated roofs store 67% more heat than wall sections. This study numerically evaluates PCMs in fabric-based emergency tents in Sistan and Baluchestan, Iran, using a passive thermal-management strategy for hot desert conditions. A two-stage CFD framework is applied: steady-state external airflow is solved with the SST k – ω turbulence model in ANSYS Fluent to obtain surface convective coefficients, while transient heat transfer inside the tent is computed via the enthalpy–porosity (mushy-zone) method, incorporating solar radiation, phase change, and buoyancy effects. Models were validated against benchmark data for PCM melting, external forced convection, and natural convection (∼7% deviation), confirming simulation reliability in capturing coupled thermal phenomena. Results show that PCM integration reduces the maximum indoor temperature from 326.75 K to 312.25 K (14.5 K/4.4% lower) and the daily average from 317.89 K to 308 K (9.89 K/3.1% lower). The peak vertical temperature difference decreases by 31%, from 17.24 K to 11.88 K. Roofs fully melted, with the West Roof storing 23.85 MJ and other PCM layers storing 16.08–19.33 MJ, while the West Wall reached ∼60% melting, yielding a total of 71.55 MJ of latent heat storage, more clearly capturing the system’s overall thermal behavior. Internal air velocities remained below 0.03 m·s −1 , indicating limited natural mixing.

Authors

Institutions

Publication Details

Journal
Thermal Science and Engineering Progress
Published
2026-02-24
DOI
https://doi.org/10.1016/j.tsep.2026.104606
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical investigation of PCM-integrated emergency tents for energy-efficient thermal management in hot desert climates

Seyed Mohammad Vahidhosseini, Roohollah Rafee, Zeinab Esmaeili, Saman Rashidi et al.
Thermal Science and Engineering Progress
Phase Change Materials Research
article

Numerical investigation of PCM-integrated emergency tents for energy-efficient thermal management in hot desert climates

Seyed Mohammad Vahidhosseini, Roohollah Rafee, Zeinab Esmaeili, Saman Rashidi, Wei-Mon Yan
article en

Abstract

• Numerical study of PCM-integrated tents for energy-efficient cooling in deserts. • CFD-based transient model addressing thermal comfort in emergency shelters. • PCM reduces indoor air stratification, lowering gradients by up to 5.4 K. • Roof PCM reaches full melting (LF ≈ 1.0) during peak solar hours. • PCM-integrated roofs store 67% more heat than wall sections. This study numerically evaluates PCMs in fabric-based emergency tents in Sistan and Baluchestan, Iran, using a passive thermal-management strategy for hot desert conditions. A two-stage CFD framework is applied: steady-state external airflow is solved with the SST k – ω turbulence model in ANSYS Fluent to obtain surface convective coefficients, while transient heat transfer inside the tent is computed via the enthalpy–porosity (mushy-zone) method, incorporating solar radiation, phase change, and buoyancy effects. Models were validated against benchmark data for PCM melting, external forced convection, and natural convection (∼7% deviation), confirming simulation reliability in capturing coupled thermal phenomena. Results show that PCM integration reduces the maximum indoor temperature from 326.75 K to 312.25 K (14.5 K/4.4% lower) and the daily average from 317.89 K to 308 K (9.89 K/3.1% lower). The peak vertical temperature difference decreases by 31%, from 17.24 K to 11.88 K. Roofs fully melted, with the West Roof storing 23.85 MJ and other PCM layers storing 16.08–19.33 MJ, while the West Wall reached ∼60% melting, yielding a total of 71.55 MJ of latent heat storage, more clearly capturing the system’s overall thermal behavior. Internal air velocities remained below 0.03 m·s −1 , indicating limited natural mixing.

Thermal Science and Engineering ProgressVol. 72
National Taipei University of Technology (TW), Semnan University (IR)
Climate action
Openalex Percentile: Top 47%
Phase Change Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.