Maximum-Likelihood--Based Position Decoding of Laser Processed Converging Pixel CsI: Tl Detectors for High-Resolution SPECT.

This study demonstrates the feasibility of a novel fabrication technique for high spatial resolution CsI: Tl scintillation detectors tailored for single photon emission computed tomography (SPECT) systems. Building upon our previously developed laser induced optical barrier (LIOB) method, which achieved high spatial resolution, excellent sensitivity, and 100% fabrication yield in CsI: Tl detectors, we extend this approach to a converging-pixel architecture. A CsI: Tl crystal array with converging pixels was designed and fabricated, featuring entrance-face pixels of 1.6x1.6 mm2 and photodetector side pixels of 2x2 mm2. To localize gamma-ray interactions, both the center of gravity (CoG) algorithm and a maximum-likelihood (ML) based decoding method were implemented. A custom built four axis motion platform was developed to deliver a finely collimated pencil beam at precisely controlled positions and angles across the array, enabling generation of a comprehensive dataset for prior knowledge and validation. The results demonstrate an energy resolution of 11.79+/-0.53% (collimated experiment) and a position localization accuracy of 1.00+/-0.42 mm (nearest neighbor interpolation), confirming that the proposed converging-pixel architecture, combined with statistical decoding algorithms, provides a promising path toward the development of high-performance SPECT detectors.

Publication Details

Journal
PubMed
Published
2026-02-09
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Maximum-Likelihood--Based Position Decoding of Laser Processed Converging Pixel CsI: Tl Detectors for High-Resolution SPECT.

PubMed
Radiation Detection and Scintillator Technologies
article

Maximum-Likelihood--Based Position Decoding of Laser Processed Converging Pixel CsI: Tl Detectors for High-Resolution SPECT.

article en

Abstract

This study demonstrates the feasibility of a novel fabrication technique for high spatial resolution CsI: Tl scintillation detectors tailored for single photon emission computed tomography (SPECT) systems. Building upon our previously developed laser induced optical barrier (LIOB) method, which achieved high spatial resolution, excellent sensitivity, and 100% fabrication yield in CsI: Tl detectors, we extend this approach to a converging-pixel architecture. A CsI: Tl crystal array with converging pixels was designed and fabricated, featuring entrance-face pixels of 1.6x1.6 mm2 and photodetector side pixels of 2x2 mm2. To localize gamma-ray interactions, both the center of gravity (CoG) algorithm and a maximum-likelihood (ML) based decoding method were implemented. A custom built four axis motion platform was developed to deliver a finely collimated pencil beam at precisely controlled positions and angles across the array, enabling generation of a comprehensive dataset for prior knowledge and validation. The results demonstrate an energy resolution of 11.79+/-0.53% (collimated experiment) and a position localization accuracy of 1.00+/-0.42 mm (nearest neighbor interpolation), confirming that the proposed converging-pixel architecture, combined with statistical decoding algorithms, provides a promising path toward the development of high-performance SPECT detectors.

PubMed
Affordable and clean energy
Openalex Percentile: Top 41%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.