Optimization strategy for multi-energy complementary heating system for hospitals in severe cold regions: A case study

The widespread adoption of a multi-energy complementary heating system leveraging excellent energy-saving and low-carbon performance is currently an effective solution to address the high energy consumption issue of hospitals in severe cold regions. However, the neglect of demand response during operation has become a serious obstacle to the sustainable operation of a multi-energy complementary heating system. A multi-energy complementary heating system integrating water-source heat pumps, coal-fired boilers, and gas-fired boilers is constructed, encompassing five energy solutions. The DeST software is used to simulate the energy consumption of the hospital, which provided a foundation for optimizing the operation strategy. Finally, the most effective energy option is suggested using the AHP-EWM-TOPSIS method for comprehensive evaluation. Results indicate that the operation strategy should be dynamically regulated according to the heat load demand. Compared with the traditional heating system, this dynamic regulation strategy can reduce CO 2 emissions and SO 2 emissions by more than 40%. It is noteworthy that WSHP-GB (water source heat pumps-gas boilers) the CO 2 emissions reduced by 70.18%, the energy saving rate reached 53.26%, and the proportion of green energy increased by 61%. Considering the four indicators of economy, technology, energy and environment comprehensively, WSHP-GB has been identified as the optimal heating scheme. Since the high-load heating demand accounts for less than 8% of the total, WSHP-GB can fully meet the basic needs during the heating period. This energy option provides a directly referable basis for the heating work of large public buildings in severe cold regions.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-02-24
DOI
https://doi.org/10.1016/j.csite.2026.107854
Primary Topic
Hygrothermal properties of building materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization strategy for multi-energy complementary heating system for hospitals in severe cold regions: A case study

Jianjian Qi, Junfeng Li, Jing Li, Yuwei Ma
Case Studies in Thermal Engineering
Hygrothermal properties of building materials
article

Optimization strategy for multi-energy complementary heating system for hospitals in severe cold regions: A case study

Jianjian Qi, Junfeng Li, Jing Li, Yuwei Ma
article en

Abstract

The widespread adoption of a multi-energy complementary heating system leveraging excellent energy-saving and low-carbon performance is currently an effective solution to address the high energy consumption issue of hospitals in severe cold regions. However, the neglect of demand response during operation has become a serious obstacle to the sustainable operation of a multi-energy complementary heating system. A multi-energy complementary heating system integrating water-source heat pumps, coal-fired boilers, and gas-fired boilers is constructed, encompassing five energy solutions. The DeST software is used to simulate the energy consumption of the hospital, which provided a foundation for optimizing the operation strategy. Finally, the most effective energy option is suggested using the AHP-EWM-TOPSIS method for comprehensive evaluation. Results indicate that the operation strategy should be dynamically regulated according to the heat load demand. Compared with the traditional heating system, this dynamic regulation strategy can reduce CO 2 emissions and SO 2 emissions by more than 40%. It is noteworthy that WSHP-GB (water source heat pumps-gas boilers) the CO 2 emissions reduced by 70.18%, the energy saving rate reached 53.26%, and the proportion of green energy increased by 61%. Considering the four indicators of economy, technology, energy and environment comprehensively, WSHP-GB has been identified as the optimal heating scheme. Since the high-load heating demand accounts for less than 8% of the total, WSHP-GB can fully meet the basic needs during the heating period. This energy option provides a directly referable basis for the heating work of large public buildings in severe cold regions.

Case Studies in Thermal EngineeringVol. 80
Shihezi University (CN), The University of Melbourne (AU)
Affordable and clean energy
Openalex Percentile: Top 46%
Hygrothermal properties of building materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.