Multidirectional lateral shearing random-step instantaneous phase-shifting interferometry for aspherical measurement

To further enhance measurement accuracy for aspheric surface wavefronts, a multi-directional lateral shearing instantaneous phase-shifting interferometry (MLSIPSI) method for aspheric surface testing is proposed by incorporating phase-shifting technology, and an MLSIPSI experimental system constructed. The experiment measured aspherical mirrors with asphericities of 4 and 10 µm, respectively, and compared the results with LUPHOSscan profilometer data. The system achieves RMS relative error accuracy better than <i>λ</i>/150, with measurement errors reduced by 27.06% and 32.05%, respectively, compared to quadriwave lateral shearing interferometry (QWLSI) baseline measurements. The experimental results verified that the validation against LUPHOScan profilometry confirmed MLSIPSI's superior precision for steep asphericity departures.

Authors

Publication Details

Journal
Applied Optics
Published
2026-02-23
DOI
https://doi.org/10.1364/ao.585648
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multidirectional lateral shearing random-step instantaneous phase-shifting interferometry for aspherical measurement

Yang Gu, Bingbing jiang, Yahui Zhu
Applied Optics
Optical measurement and interference techniques
article

Multidirectional lateral shearing random-step instantaneous phase-shifting interferometry for aspherical measurement

Yang Gu, Bingbing jiang, Yahui Zhu
article en

Abstract

To further enhance measurement accuracy for aspheric surface wavefronts, a multi-directional lateral shearing instantaneous phase-shifting interferometry (MLSIPSI) method for aspheric surface testing is proposed by incorporating phase-shifting technology, and an MLSIPSI experimental system constructed. The experiment measured aspherical mirrors with asphericities of 4 and 10 µm, respectively, and compared the results with LUPHOSscan profilometer data. The system achieves RMS relative error accuracy better than <i>λ</i>/150, with measurement errors reduced by 27.06% and 32.05%, respectively, compared to quadriwave lateral shearing interferometry (QWLSI) baseline measurements. The experimental results verified that the validation against LUPHOScan profilometry confirmed MLSIPSI's superior precision for steep asphericity departures.

Applied OpticsVol. 65(9)
Openalex Percentile: Top 48%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.