Intermediate temperature proton exchange membrane fuel cells: a systematic review of recently electrochemically evaluated materials

The integration of proton exchange membrane fuel cells (PEMFCs) in heavy-duty vehicles and other demanding applications, such as aviation, would be simplified if the stacks could operate above 100 °C instead of the traditional low temperature (LT, up to 80 °C), thereby allowing a reduction in cooling system in size and power. This review offers a comprehensive compilation of experimental studies reported in the literature on PEMFCs operated in the intermediate temperature (IT)-range, here defined as above 80 °C and up to 120 °C, which represented the targeted upper temperature for PEMFCs. Membranes, electrodes and gas diffusion layers for IT-PEMFCs are discussed. Particular attention is paid to polymers in membranes and catalyst layer ionomers. Results from current state-of-the-art perfluorosulfonic acids and alternatives, including hydrocarbon polymers, are evaluated considering their properties and limitations. Further, system benefits and drawbacks of IT- compared to the traditional LT-operation are discussed, such as the interplay between vapour and oxygen pressure, hydrogen crossover and water management. We report on the lack of consistency between ex-situ and in-situ studies and underline the importance of in-situ tests, proposing guidelines to evaluate novel materials. For IT-operation, the development of stable polymers, which are the weakest components of the PEMFCs, is the most urgent challenge. As degradation happens faster at higher temperatures, further long-term tests are needed above 80 °C and accelerated stress tests should be specifically designed for IT-operation according to the polymer chemistries. We conclude that, compared to LT-, IT-operation requires improved materials and additional research. • Review of in-situ electrochemical tested proton exchange membrane fuel cells (PEMFCs). • We define the operating temperature range 80—120°C as Intermediate temperature (IT). • Performance of PFSA- and hydrocarbon-based polymers is reported systematically. • Considerations on crossover, heat and water management when operating PEMFCs at IT. • We discuss IT-operation implications for heavy-duty vehicles and other applications.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2026-02-24
DOI
https://doi.org/10.1016/j.apenergy.2026.127499
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intermediate temperature proton exchange membrane fuel cells: a systematic review of recently electrochemically evaluated materials

Pontus Svens, Marcus Ringström, John G. Petrovick, Martina Butori et al.
Applied Energy
Fuel Cells and Related Materials
article

Intermediate temperature proton exchange membrane fuel cells: a systematic review of recently electrochemically evaluated materials

Pontus Svens, Marcus Ringström, John G. Petrovick, Martina Butori, Patric Jannasch, Marcus Liljenberg, Rakel Wreland Lindström, Carina Lagergren, Göran Lindbergh, Björn Eriksson
article en

Abstract

The integration of proton exchange membrane fuel cells (PEMFCs) in heavy-duty vehicles and other demanding applications, such as aviation, would be simplified if the stacks could operate above 100 °C instead of the traditional low temperature (LT, up to 80 °C), thereby allowing a reduction in cooling system in size and power. This review offers a comprehensive compilation of experimental studies reported in the literature on PEMFCs operated in the intermediate temperature (IT)-range, here defined as above 80 °C and up to 120 °C, which represented the targeted upper temperature for PEMFCs. Membranes, electrodes and gas diffusion layers for IT-PEMFCs are discussed. Particular attention is paid to polymers in membranes and catalyst layer ionomers. Results from current state-of-the-art perfluorosulfonic acids and alternatives, including hydrocarbon polymers, are evaluated considering their properties and limitations. Further, system benefits and drawbacks of IT- compared to the traditional LT-operation are discussed, such as the interplay between vapour and oxygen pressure, hydrogen crossover and water management. We report on the lack of consistency between ex-situ and in-situ studies and underline the importance of in-situ tests, proposing guidelines to evaluate novel materials. For IT-operation, the development of stable polymers, which are the weakest components of the PEMFCs, is the most urgent challenge. As degradation happens faster at higher temperatures, further long-term tests are needed above 80 °C and accelerated stress tests should be specifically designed for IT-operation according to the polymer chemistries. We conclude that, compared to LT-, IT-operation requires improved materials and additional research. • Review of in-situ electrochemical tested proton exchange membrane fuel cells (PEMFCs). • We define the operating temperature range 80—120°C as Intermediate temperature (IT). • Performance of PFSA- and hydrocarbon-based polymers is reported systematically. • Considerations on crossover, heat and water management when operating PEMFCs at IT. • We discuss IT-operation implications for heavy-duty vehicles and other applications.

Applied EnergyVol. 410
Lund University (SE), Södertälje Sjukhus (SE), PowerCell (Sweden) (SE), KTH Royal Institute of Technology (SE)
Affordable and clean energy
Openalex Percentile: Top 47%
Fuel Cells and Related Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.