Impact of surface-guided prepositioning and respiratory coaching on the target localization accuracy in lung stereotactic body radiation therapy

This study assessed the effect of surface-guided radiation therapy (SGRT)-based prepositioning and respiratory coaching on target localization accuracy in lung stereotactic body radiation therapy (SBRT) using deep inspiration breath-holding. Thirty-five patients treated with lung SBRT (September 2022 to March 2025) were classified into three groups: Group A, VOXELAN prepositioning with reproducible respiratory control (≥ 60% setup criteria satisfied); Group B, VOXELAN prepositioning without reproducible control; and Group C, no VOXELAN prepositioning. Cone-beam computed tomography (CBCT) after prepositioning was used to retrospectively assess target localization. The concordance between the VOXELAN setup criteria and CBCT errors (> 5 mm) was analyzed using Fisher's exact test. Positional deviations and rotations were compared among groups using analysis of variance and post-hoc tests. Satisfying the VOXELAN setup criteria significantly correlated with CBCT localization within 5 mm (p = 0.0027). Vertical errors were smaller in Groups A and B than in Group C (p < 0.01), and lateral errors were smaller in Groups A and B than in Group C (p = 0.01 and p < 0.01, respectively). Rotational errors were within ± 1° in all groups, with a significant difference between Groups A and C (p < 0.02). Longitudinal errors were not significantly different between the groups. SGRT-based prepositioning with respiratory coaching improved setup reproducibility and correlation with the internal target position, particularly in the vertical, lateral, and rotational axes. Longitudinal accuracy remained limited, suggesting caution in margin reduction.

Authors

Institutions

Publication Details

Journal
Radiological Physics and Technology
Published
2026-02-23
DOI
https://doi.org/10.1007/s12194-026-01008-2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of surface-guided prepositioning and respiratory coaching on the target localization accuracy in lung stereotactic body radiation therapy

Kazuki Onishi, Yuta Muraki, Naoki Hayashi, Shinya Neri et al.
Radiological Physics and Technology
Advanced Radiotherapy Techniques
article

Impact of surface-guided prepositioning and respiratory coaching on the target localization accuracy in lung stereotactic body radiation therapy

Kazuki Onishi, Yuta Muraki, Naoki Hayashi, Shinya Neri, M Nozue, Tatsunori Saito
article en

Abstract

This study assessed the effect of surface-guided radiation therapy (SGRT)-based prepositioning and respiratory coaching on target localization accuracy in lung stereotactic body radiation therapy (SBRT) using deep inspiration breath-holding. Thirty-five patients treated with lung SBRT (September 2022 to March 2025) were classified into three groups: Group A, VOXELAN prepositioning with reproducible respiratory control (≥ 60% setup criteria satisfied); Group B, VOXELAN prepositioning without reproducible control; and Group C, no VOXELAN prepositioning. Cone-beam computed tomography (CBCT) after prepositioning was used to retrospectively assess target localization. The concordance between the VOXELAN setup criteria and CBCT errors (> 5 mm) was analyzed using Fisher's exact test. Positional deviations and rotations were compared among groups using analysis of variance and post-hoc tests. Satisfying the VOXELAN setup criteria significantly correlated with CBCT localization within 5 mm (p = 0.0027). Vertical errors were smaller in Groups A and B than in Group C (p < 0.01), and lateral errors were smaller in Groups A and B than in Group C (p = 0.01 and p < 0.01, respectively). Rotational errors were within ± 1° in all groups, with a significant difference between Groups A and C (p < 0.02). Longitudinal errors were not significantly different between the groups. SGRT-based prepositioning with respiratory coaching improved setup reproducibility and correlation with the internal target position, particularly in the vertical, lateral, and rotational axes. Longitudinal accuracy remained limited, suggesting caution in margin reduction.

Radiological Physics and Technology
Fujita Health University Hospital (JP), Seirei Hamamatsu General Hospital (JP)
Openalex Percentile: Top 41%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.