Calculating dim light melatonin onset in children: A comparison of four estimation methods

Dim light melatonin onset (DLMO) is the gold standard circadian phase marker in humans. Although several methods can be employed to estimate DLMO, no research has compared agreement across methods using data from pediatric populations. Here, we compared salivary DLMO calculated using four different methods, including two fixed thresholds (3 pg/ml and 4 pg/ml) and two individual thresholds (2 SD above baseline and the "hockey stick" method) in data from 49 children (<i>M</i> = 4.40 ± 0.66 y, 57% female). Intraclass correlations among the four methods were all significant (<i>p</i> < 0.001), with the strongest agreement observed between the 3 pg/ml, 4 pg/ml, and hockey stick methods. DLMO values from all methods were positively correlated with sleep timing (<i>p</i> < 0.001). Although the 2 SD method was more discrepant from the other three estimation methods on average, it did yield a more plausible DLMO estimate in one individual identified as a high secretor. Overall, our findings suggest the 3 pg/ml, 4 pg/ml, and hockey stick methods provide reliable estimates of DLMO in young children, whereas the 2 SD method may allow a more accurate DLMO estimation in edge cases of high or low melatonin secretors.

Authors

Institutions

Publication Details

Journal
Chronobiology International
Published
2026-02-23
DOI
https://doi.org/10.1080/07420528.2026.2633233
Primary Topic
Circadian rhythm and melatonin
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculating dim light melatonin onset in children: A comparison of four estimation methods

Rebecca C. Cox, Isabella Sagman, Lauren E Hartstein
Chronobiology International
Circadian rhythm and melatonin
article

Calculating dim light melatonin onset in children: A comparison of four estimation methods

Rebecca C. Cox, Isabella Sagman, Lauren E Hartstein
article en

Abstract

Dim light melatonin onset (DLMO) is the gold standard circadian phase marker in humans. Although several methods can be employed to estimate DLMO, no research has compared agreement across methods using data from pediatric populations. Here, we compared salivary DLMO calculated using four different methods, including two fixed thresholds (3 pg/ml and 4 pg/ml) and two individual thresholds (2 SD above baseline and the "hockey stick" method) in data from 49 children (<i>M</i> = 4.40 ± 0.66 y, 57% female). Intraclass correlations among the four methods were all significant (<i>p</i> < 0.001), with the strongest agreement observed between the 3 pg/ml, 4 pg/ml, and hockey stick methods. DLMO values from all methods were positively correlated with sleep timing (<i>p</i> < 0.001). Although the 2 SD method was more discrepant from the other three estimation methods on average, it did yield a more plausible DLMO estimate in one individual identified as a high secretor. Overall, our findings suggest the 3 pg/ml, 4 pg/ml, and hockey stick methods provide reliable estimates of DLMO in young children, whereas the 2 SD method may allow a more accurate DLMO estimation in edge cases of high or low melatonin secretors.

Chronobiology International
Vassar College (US), University of Arizona (US), University of Colorado Boulder (US), Washington University in St. Louis (US), University of Colorado System (US)
Openalex Percentile: Top 43%
Circadian rhythm and melatonin
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.