Apparent inertia reduction via force sensorless impedance control

In interactive robot tasks, virtual compliance at the interaction port is often achieved using impedance control. The impedance controller can be extended with force feedback to adjust the inertia at the interaction port, classically done using a force sensor. In cases where forces cannot be measured accurately, a disturbance observer (DOB) can be employed. In this work, we propose to extend the classical inertia shaping controller with a DOB and investigate the limits of mass rendering. We analyse passivity using mechanical equivalents and stability using Hurwitz analysis. We also compare the DOB-based impedance controller with optimal results from H 2 and μ -synthesis on a dedicated 2-Degrees-of-Freedom (DoF) experimental setup with an internal parasitic mode. The results highlight a clear trade-off between inertia reduction, robust stability and performance. Although the DOB-based controller provides an intuitive design, H 2 allows to increase the bandwidth, while μ -synthesis improves robustness. • Apparent inertia reduction by extending impedance control with a disturbance observer. • Apparent inertia reduction limits governed by bandwidth and internal mode. • Improved stability robustness for apparent inertia reduction by H2 and μ -synthesis • Experimental validation and comparison on custom single-axis setup with internal mode.

Authors

Institutions

Publication Details

Journal
Mechatronics
Published
2026-02-23
DOI
https://doi.org/10.1016/j.mechatronics.2026.103486
Primary Topic
Teleoperation and Haptic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Apparent inertia reduction via force sensorless impedance control

Marijn Nijenhuis, Wouter Hakvoort, B. Gerlagh
Mechatronics
Teleoperation and Haptic Systems
article

Apparent inertia reduction via force sensorless impedance control

Marijn Nijenhuis, Wouter Hakvoort, B. Gerlagh
article en

Abstract

In interactive robot tasks, virtual compliance at the interaction port is often achieved using impedance control. The impedance controller can be extended with force feedback to adjust the inertia at the interaction port, classically done using a force sensor. In cases where forces cannot be measured accurately, a disturbance observer (DOB) can be employed. In this work, we propose to extend the classical inertia shaping controller with a DOB and investigate the limits of mass rendering. We analyse passivity using mechanical equivalents and stability using Hurwitz analysis. We also compare the DOB-based impedance controller with optimal results from H 2 and μ -synthesis on a dedicated 2-Degrees-of-Freedom (DoF) experimental setup with an internal parasitic mode. The results highlight a clear trade-off between inertia reduction, robust stability and performance. Although the DOB-based controller provides an intuitive design, H 2 allows to increase the bandwidth, while μ -synthesis improves robustness. • Apparent inertia reduction by extending impedance control with a disturbance observer. • Apparent inertia reduction limits governed by bandwidth and internal mode. • Improved stability robustness for apparent inertia reduction by H2 and μ -synthesis • Experimental validation and comparison on custom single-axis setup with internal mode.

MechatronicsVol. 116
University of Twente (NL)
Peace, Justice and strong institutions
Openalex Percentile: Top 48%
Teleoperation and Haptic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.