Anesthetic considerations for TAVR in a patient with HeartMate 3: A case report

Severe aortic insufficiency (AI) is associated with well-known pathophysiologic consequences related to onset acuity, with the possibility of pulmonary congestion and cardiogenic shock. The presence of AI in patients with continuous flow left ventricular assist device (LVAD) creates unique physiologic challenges due to recirculation of LVAD flow, rather than contributing to cardiac output. Correction of AI in patients with LVADs typically includes open surgical aortic valve replacement (SAVR). Prior sternotomy with resultant adhesions, as well as the presence of a mechanical circulatory support device, complicates surgical AVR and carries higher operative morbidity and mortality. While TAVR in patients with LVADs has been performed successfully, the procedure carries significant procedural risk related to retrograde valve embolization and potential disruption of LVAD inflow cannula. To date, there are no published studies outlining the optimal HeartMate 3 (HM3, Abbott, Chicago IL) LVAD parameters for valve deployment. This case report outlines HM3 flow, speed, and the pacing parameters used for successful deployment of a CoreValve Evolut Pro+ in a patient with severe AI.

Authors

Institutions

Publication Details

Journal
JCA advances.
Published
2026-02-23
DOI
https://doi.org/10.1016/j.jcadva.2026.100213
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anesthetic considerations for TAVR in a patient with HeartMate 3: A case report

William C. Culp, Stavroula Ikonomakou-Nikolaidis, M'Kay Cauble, Sarven Tersakyan et al.
JCA advances.
Cardiac Valve Diseases and Treatments
article

Anesthetic considerations for TAVR in a patient with HeartMate 3: A case report

William C. Culp, Stavroula Ikonomakou-Nikolaidis, M'Kay Cauble, Sarven Tersakyan, Shiloh Sorenson
article en

Abstract

Severe aortic insufficiency (AI) is associated with well-known pathophysiologic consequences related to onset acuity, with the possibility of pulmonary congestion and cardiogenic shock. The presence of AI in patients with continuous flow left ventricular assist device (LVAD) creates unique physiologic challenges due to recirculation of LVAD flow, rather than contributing to cardiac output. Correction of AI in patients with LVADs typically includes open surgical aortic valve replacement (SAVR). Prior sternotomy with resultant adhesions, as well as the presence of a mechanical circulatory support device, complicates surgical AVR and carries higher operative morbidity and mortality. While TAVR in patients with LVADs has been performed successfully, the procedure carries significant procedural risk related to retrograde valve embolization and potential disruption of LVAD inflow cannula. To date, there are no published studies outlining the optimal HeartMate 3 (HM3, Abbott, Chicago IL) LVAD parameters for valve deployment. This case report outlines HM3 flow, speed, and the pacing parameters used for successful deployment of a CoreValve Evolut Pro+ in a patient with severe AI.

JCA advances.Vol. 3(2)
Baylor Scott & White Medical Center - Temple (US)
Gender equality
Openalex Percentile: Top 50%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.