Self-calibrated stitching metrology for X-ray flat mirrors with the power- <i>x</i> term calibrated by grazing-incidence absolute testing

Shear-shift self-calibration stitching interferometry for long X-ray flat mirrors cannot reliably recover the meridional power-<i>x</i> term (<i>x</i><sup>2</sup>). Calibrating the reference-flat power term and then stitching amplifies any residual power error to an unacceptable level for extreme X-ray optics. We demonstrate a hybrid absolute metrology in which a full-field grazing-incidence absolute test directly measures the power-<i>x</i> term, while a two-dimensional self-calibration stitching procedure determines the remaining surface components at high spatial resolution. This hybrid strategy removes the power-term ambiguity in self-calibration stitching and prohibits the power-error amplification in traditional stitching for long flats. On a 300 × 60 mm mirror (288 × 40 mm clear aperture), the reconstructed absolute surface shows 0.75 nm PV and 0.07 nm RMS repeatability, and the central profile agrees with a slope profiler at the sub-nanometer level.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2026-02-23
DOI
https://doi.org/10.1364/ol.588584
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-calibrated stitching metrology for X-ray flat mirrors with the power- x term calibrated by grazing-incidence absolute testing

Yudong Mao, Zubo Hu, Shuai Xue, Hao Yu
Optics Letters
Advanced X-ray Imaging Techniques
article

Self-calibrated stitching metrology for X-ray flat mirrors with the power- x term calibrated by grazing-incidence absolute testing

Yudong Mao, Zubo Hu, Shuai Xue, Hao Yu
article en

Abstract

Shear-shift self-calibration stitching interferometry for long X-ray flat mirrors cannot reliably recover the meridional power-<i>x</i> term (<i>x</i><sup>2</sup>). Calibrating the reference-flat power term and then stitching amplifies any residual power error to an unacceptable level for extreme X-ray optics. We demonstrate a hybrid absolute metrology in which a full-field grazing-incidence absolute test directly measures the power-<i>x</i> term, while a two-dimensional self-calibration stitching procedure determines the remaining surface components at high spatial resolution. This hybrid strategy removes the power-term ambiguity in self-calibration stitching and prohibits the power-error amplification in traditional stitching for long flats. On a 300 × 60 mm mirror (288 × 40 mm clear aperture), the reconstructed absolute surface shows 0.75 nm PV and 0.07 nm RMS repeatability, and the central profile agrees with a slope profiler at the sub-nanometer level.

Optics LettersVol. 51(6)
National University of Defense Technology (CN)
Zero hunger
Openalex Percentile: Top 41%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.