Abstract This study investigates a novel solar-driven triple-generation Kalina cycle designed to supply electricity, cooling, and heating under Kabul's climatic conditions. The problem addressed is the lack of a comprehensive thermodynamic, economic, and environmental evaluation for such multi-generation systems, particularly when solar storage plays a dominant role in the system performance. To fill this gap, the research conducts—for the first time—a fully integrated conventional and advanced exergy, exergoeconomic, and exergoenvironmental analysis of a solar-assisted triple-generation Kalina cycle. A detailed thermodynamic model was developed in ees to simulate summer and winter conditions. The advanced exergy results show that the solar thermal tank in summer and the auxiliary boiler in winter are the major sources of irreversibility; however, a substantial portion of these destructions is avoidable and exogenous (e.g., 4553 kW in summer), indicating that system-wide optimization, rather than isolated component improvements, offers the highest potential for performance enhancement. Exergoeconomic results reveal that destruction costs associated with the thermal tank (1698.8 USD/h in summer) and solar-storage investment (3077 USD/h in summer) and solar-storage investment (3077 USD/h) are the dominant contributors to total cost, implying that improved storage design is essential for long-term economic feasibility. From an environmental standpoint, the auxiliary boiler generates the highest impacts (up to 302.8 Pts/h), suggesting that low-emission fuel alternatives or boiler-side enhancements are critical. Overall, the system demonstrates strong potential for sustainable and cost-effective energy supply, meaning that improvements targeting avoidable and exogenous losses—especially within the storage and boiler subsystems—can significantly increase efficiency while reducing economic and environmental burdens.

Authors

Institutions

Publication Details

Journal
Journal of Solar Energy Engineering
Published
2026-02-23
DOI
https://doi.org/10.1115/1.4071192
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced Exergy, Exergoeconomic, and Exergoenvironmental Analysis of a Solar-Driven Triple-Generation Kalina Cycle

Sikata Samantaray, Yashwant Singh Bisht, Rita Singh, Tariq Abdulkader Alrihaim et al.
Journal of Solar Energy Engineering
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Advanced Exergy, Exergoeconomic, and Exergoenvironmental Analysis of a Solar-Driven Triple-Generation Kalina Cycle

Sikata Samantaray, Yashwant Singh Bisht, Rita Singh, Tariq Abdulkader Alrihaim, Ibrahim Khersan, Sujai S, Jino L, Mustafa Abdullah
article en

Abstract

Abstract This study investigates a novel solar-driven triple-generation Kalina cycle designed to supply electricity, cooling, and heating under Kabul's climatic conditions. The problem addressed is the lack of a comprehensive thermodynamic, economic, and environmental evaluation for such multi-generation systems, particularly when solar storage plays a dominant role in the system performance. To fill this gap, the research conducts—for the first time—a fully integrated conventional and advanced exergy, exergoeconomic, and exergoenvironmental analysis of a solar-assisted triple-generation Kalina cycle. A detailed thermodynamic model was developed in ees to simulate summer and winter conditions. The advanced exergy results show that the solar thermal tank in summer and the auxiliary boiler in winter are the major sources of irreversibility; however, a substantial portion of these destructions is avoidable and exogenous (e.g., 4553 kW in summer), indicating that system-wide optimization, rather than isolated component improvements, offers the highest potential for performance enhancement. Exergoeconomic results reveal that destruction costs associated with the thermal tank (1698.8 USD/h in summer) and solar-storage investment (3077 USD/h in summer) and solar-storage investment (3077 USD/h) are the dominant contributors to total cost, implying that improved storage design is essential for long-term economic feasibility. From an environmental standpoint, the auxiliary boiler generates the highest impacts (up to 302.8 Pts/h), suggesting that low-emission fuel alternatives or boiler-side enhancements are critical. Overall, the system demonstrates strong potential for sustainable and cost-effective energy supply, meaning that improvements targeting avoidable and exogenous losses—especially within the storage and boiler subsystems—can significantly increase efficiency while reducing economic and environmental burdens.

Journal of Solar Energy EngineeringVol. 148(3)
Chandigarh University (IN), Al-Ahliyya Amman University (JO), Jain University (IN), Siksha O Anusandhan University (IN), Uttaranchal University (IN), Islamic University (BD), University of Petroleum (ID), Sathyabama Institute of Science and Technology (IN)
Openalex Percentile: Top 48%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.