Predictive modeling correlates flow rate and residence time with measurement precision in two-detector Taylor dispersion analysis

Taylor dispersion analysis (TDA) provides calibration-free measurements of particle or molecular size by characterizing band broadening induced by the interaction of diffusion and pressure-driven laminar flow. Appropriate flow for TDA analyses is conventionally defined by Taylor's conditions, which set thresholds related to flow velocity (Pe ≥ 69) and residence time (τ > 2.5). Optimizing these parameters is complicated by the fact that they are covariant when detector position is a fixed instrumental constraint. Previous reports have reconsidered these conditions, but consensus is lacking on appropriate threshold values and on their relative contributions to measurement performance, especially in the context of capillary TDA with two detection points. Here, we describe a statistically driven experimental study of the interaction between residence time and flow velocity and the impact of this interaction on measurement precision in two-detector TDA. A six-detector array achieving 15 unique τ values per analysis was used to generate a dataset of 1200 TDA measurements across three volumetric flow rates. Two analytes, Alexafluor 532 (AF532) and R-phycoerythrin (RPE), were selected as models to bracket a pragmatic range of hydrodynamic radii (R<sub>h</sub>) for biomolecular sizing. A strategy of iterative regression modeling with random subsampling was applied to generate a predictive model describing the effects of flow velocity and residence time on relative measurement precision. Experimental conditions based on the predictive model showed improved measurement precision for AF532 from 9 to 6% RSD, and for RPE from 24 to 12% RSD. External validation using non-training data showed precision improvements of 9.4% to 8.5% RSD for size measurements of a synthetic ssDNA oligonucleotide. The predictive model suggests that prioritizing flow velocity when designing two-detector TDA experiments may offer an efficient route to improved measurement precision.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2026-02-23
DOI
https://doi.org/10.1007/s00216-026-06376-7
Primary Topic
Groundwater flow and contamination studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predictive modeling correlates flow rate and residence time with measurement precision in two-detector Taylor dispersion analysis

Hillary D. Bourger, Christopher A. Baker
Analytical and Bioanalytical Chemistry
Groundwater flow and contamination studies
article

Predictive modeling correlates flow rate and residence time with measurement precision in two-detector Taylor dispersion analysis

Hillary D. Bourger, Christopher A. Baker
article en

Abstract

Taylor dispersion analysis (TDA) provides calibration-free measurements of particle or molecular size by characterizing band broadening induced by the interaction of diffusion and pressure-driven laminar flow. Appropriate flow for TDA analyses is conventionally defined by Taylor's conditions, which set thresholds related to flow velocity (Pe ≥ 69) and residence time (τ > 2.5). Optimizing these parameters is complicated by the fact that they are covariant when detector position is a fixed instrumental constraint. Previous reports have reconsidered these conditions, but consensus is lacking on appropriate threshold values and on their relative contributions to measurement performance, especially in the context of capillary TDA with two detection points. Here, we describe a statistically driven experimental study of the interaction between residence time and flow velocity and the impact of this interaction on measurement precision in two-detector TDA. A six-detector array achieving 15 unique τ values per analysis was used to generate a dataset of 1200 TDA measurements across three volumetric flow rates. Two analytes, Alexafluor 532 (AF532) and R-phycoerythrin (RPE), were selected as models to bracket a pragmatic range of hydrodynamic radii (R<sub>h</sub>) for biomolecular sizing. A strategy of iterative regression modeling with random subsampling was applied to generate a predictive model describing the effects of flow velocity and residence time on relative measurement precision. Experimental conditions based on the predictive model showed improved measurement precision for AF532 from 9 to 6% RSD, and for RPE from 24 to 12% RSD. External validation using non-training data showed precision improvements of 9.4% to 8.5% RSD for size measurements of a synthetic ssDNA oligonucleotide. The predictive model suggests that prioritizing flow velocity when designing two-detector TDA experiments may offer an efficient route to improved measurement precision.

Analytical and Bioanalytical Chemistry
New Mexico State University (US)
National Science Foundation, National Institutes of Health, National Institute of General Medical Sciences, Division of Chemistry
Openalex Percentile: Top 54%
Groundwater flow and contamination studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.