Nine Years of UVIT: Assessing Sensitivity Variation

Abstract The Ultra-Violet Imaging Telescope (UVIT) is one of the five payloads on board the first Indian multiwavelength astronomical observatory, AstroSat, launched by the Indian Space Research Organisation on 2015 September 28. UVIT, designed for simultaneous imaging in the far-ultraviolet (FUV; 1300−1800 Å) and near-ultraviolet (NUV; 2000−3000 Å) channels, has completed 9 yr in orbit in 2024 despite the failure of the NUV channel in 2018. As the FUV optics is subject to possible reduction in sensitivity due to microscopic amounts of contaminants, we used the FUV data acquired by UVIT over the past 9 yr on the open cluster NGC 188 and the white dwarf HZ 4 to study sensitivity variations in the UVIT FUV channel. Our findings indicate no significant reduction in the sensitivity of the FUV channel over the last 9 yr, with no significant episodic variations due to unknown causes.

Authors

Publication Details

Journal
The Astronomical Journal
Published
2026-02-23
DOI
https://doi.org/10.3847/1538-3881/ae38d5
Primary Topic
Astronomy and Astrophysical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nine Years of UVIT: Assessing Sensitivity Variation

Akanksha Dagore, Prajwel Joseph, S. N. Tandon, S. K. Ghosh et al.
The Astronomical Journal
Astronomy and Astrophysical Research
article

Nine Years of UVIT: Assessing Sensitivity Variation

Akanksha Dagore, Prajwel Joseph, S. N. Tandon, S. K. Ghosh, C. S. Stalin, Annapurni Subramaniam
article en

Abstract

Abstract The Ultra-Violet Imaging Telescope (UVIT) is one of the five payloads on board the first Indian multiwavelength astronomical observatory, AstroSat, launched by the Indian Space Research Organisation on 2015 September 28. UVIT, designed for simultaneous imaging in the far-ultraviolet (FUV; 1300−1800 Å) and near-ultraviolet (NUV; 2000−3000 Å) channels, has completed 9 yr in orbit in 2024 despite the failure of the NUV channel in 2018. As the FUV optics is subject to possible reduction in sensitivity due to microscopic amounts of contaminants, we used the FUV data acquired by UVIT over the past 9 yr on the open cluster NGC 188 and the white dwarf HZ 4 to study sensitivity variations in the UVIT FUV channel. Our findings indicate no significant reduction in the sensitivity of the FUV channel over the last 9 yr, with no significant episodic variations due to unknown causes.

The Astronomical JournalVol. 171(3)
Openalex Percentile: Top 50%
Astronomy and Astrophysical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.