Overcoming fading in passive dosimetry: A combined persistent-luminescence and residual-thermoluminescence method

Thermoluminescence (TL) and optically stimulated luminescence are widely used in radiation dosimetry. In applying these methods, signal fading is a major source of error in dose estimation. Hypothetically, a material whose conventional TL fades significantly due to spontaneous detrapping of electrons should produce persistent luminescence (PerL) as the electrons recombine radiatively with holes. If the material is heated after measurement of PerL, the resulting TL (RTL) is due to the residual population of trapped electrons. Therefore, combining PerL and RTL may provide reliable information on radiation dose. This paper proposes a versatile method of evaluating radiation dose intended to overcome the issue of fading. The hypothesis was tested using (BaAl2O4–BaAl12O19):Eu2+, a mixed-phase phosphor. This phosphor has a continuous distribution of electron traps with an energy depth range 0.59–1.17 eV below the conduction band. In addition to conventional TL, the phosphor produces intense PerL as well as RTL and has a linear dose response between 1 and 15 Gy. The hypothesis was, thus, tested for five test doses, namely, 2, 4, 8, 11, and 14 Gy. The values of these test doses as estimated using conventional TL are 2.17 ± 0.01, 4.08 ± 0.01, 7.95 ± 0.01, 10.96 ± 0.01, and 14.12 ± 0.01 Gy, respectively. In comparison, the combined use of PerL and RTL retained them as 2.05 ± 0.02, 4.04 ± 0.02, 8.02 ± 0.02, 10.98 ± 0.02, and 13.99 ± 0.02 Gy, respectively. For all test doses, the discrepancies in doses recovered using conventional TL exceed those estimated using combined PerL and RTL, thus making the later a reliable alternative method for dosimetry.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physics
Published
2026-02-23
DOI
https://doi.org/10.1063/5.0309598
Primary Topic
Luminescence Properties of Advanced Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Overcoming fading in passive dosimetry: A combined persistent-luminescence and residual-thermoluminescence method

M. P. Kalita, M. L. Chithambo, J. M. Kalita
Journal of Applied Physics
Luminescence Properties of Advanced Materials
article

Overcoming fading in passive dosimetry: A combined persistent-luminescence and residual-thermoluminescence method

M. P. Kalita, M. L. Chithambo, J. M. Kalita
article en

Abstract

Thermoluminescence (TL) and optically stimulated luminescence are widely used in radiation dosimetry. In applying these methods, signal fading is a major source of error in dose estimation. Hypothetically, a material whose conventional TL fades significantly due to spontaneous detrapping of electrons should produce persistent luminescence (PerL) as the electrons recombine radiatively with holes. If the material is heated after measurement of PerL, the resulting TL (RTL) is due to the residual population of trapped electrons. Therefore, combining PerL and RTL may provide reliable information on radiation dose. This paper proposes a versatile method of evaluating radiation dose intended to overcome the issue of fading. The hypothesis was tested using (BaAl2O4–BaAl12O19):Eu2+, a mixed-phase phosphor. This phosphor has a continuous distribution of electron traps with an energy depth range 0.59–1.17 eV below the conduction band. In addition to conventional TL, the phosphor produces intense PerL as well as RTL and has a linear dose response between 1 and 15 Gy. The hypothesis was, thus, tested for five test doses, namely, 2, 4, 8, 11, and 14 Gy. The values of these test doses as estimated using conventional TL are 2.17 ± 0.01, 4.08 ± 0.01, 7.95 ± 0.01, 10.96 ± 0.01, and 14.12 ± 0.01 Gy, respectively. In comparison, the combined use of PerL and RTL retained them as 2.05 ± 0.02, 4.04 ± 0.02, 8.02 ± 0.02, 10.98 ± 0.02, and 13.99 ± 0.02 Gy, respectively. For all test doses, the discrepancies in doses recovered using conventional TL exceed those estimated using combined PerL and RTL, thus making the later a reliable alternative method for dosimetry.

Journal of Applied PhysicsVol. 139(8)
Rhodes University (ZA), Cotton University (IN)
Affordable and clean energy
Openalex Percentile: Top 48%
Luminescence Properties of Advanced Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.