Commissioning and Performance Evaluation of Varian TrueBeam Linear Accelerator

Aim: The aim of this study is to present a report on the commissioning results of the Varian TrueBeam machine with available photon energies so that it can benefit medical physicists during the entire commissioning process. Subjects and Methods: All tests were performed as per the recommendation of the Atomic Energy Regulatory Board. The beam profiles and percentage depth dose of both photon and electron beams were measured with Sun nuclear Radiation Field Analyzer and 0.125 cc ionization chamber. Output accuracy and consistency of photon and electron beams were measured using 0.6 cc cylindrical ionization chamber and 0.350 cc parallel plate ionization chamber, respectively. To measure the congruency of radiation and optical field and isocenter check with respect to gantry, collimator, and couch, self‑developed films were used. Results: Isocenter shift due to gantry, collimator, and couch, rotation was found to be within ± 2‑mm diameter circle. Congruency of optical and radiation fields was measured for symmetric fields 5 cm × 5 cm, 10 cm × 10 cm, 20 cm × 20 cm, and 30 cm × 30 cm for all available energy and was within ± 2 mm. Dosimetric leaf gap value for the multi‑leaf collimator was measured with 0.125 cc ionization chamber and values are −0.853 mm, −1.106 mm, −1.097 mm, −0.765 mm, and −1.005 mm for energies 6 MV, 10 MV, 15 MV, 6 flattening filter free (FFF), and 10 FFF, respectively. Conclusions: All electrical, mechanical, dosimetric, and safety measurement were found to be within permissible limits. Before clinical use, the beam data are crosschecked with point dosimetry, portal dosimetry, and MapCHECK two‑dimensional detector array and results are within tolerance.

Authors

Institutions

Publication Details

Published
2026-02-04
DOI
https://doi.org/10.82339/jrmt.vol4no1.27
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Commissioning and Performance Evaluation of Varian TrueBeam Linear Accelerator

Phulkumari Talukdar, Bidisha Dutta, Shrutisikha Goswami, Sushmita Moran
Advanced Radiotherapy Techniques
article

Commissioning and Performance Evaluation of Varian TrueBeam Linear Accelerator

Phulkumari Talukdar, Bidisha Dutta, Shrutisikha Goswami, Sushmita Moran
article en

Abstract

Aim: The aim of this study is to present a report on the commissioning results of the Varian TrueBeam machine with available photon energies so that it can benefit medical physicists during the entire commissioning process. Subjects and Methods: All tests were performed as per the recommendation of the Atomic Energy Regulatory Board. The beam profiles and percentage depth dose of both photon and electron beams were measured with Sun nuclear Radiation Field Analyzer and 0.125 cc ionization chamber. Output accuracy and consistency of photon and electron beams were measured using 0.6 cc cylindrical ionization chamber and 0.350 cc parallel plate ionization chamber, respectively. To measure the congruency of radiation and optical field and isocenter check with respect to gantry, collimator, and couch, self‑developed films were used. Results: Isocenter shift due to gantry, collimator, and couch, rotation was found to be within ± 2‑mm diameter circle. Congruency of optical and radiation fields was measured for symmetric fields 5 cm × 5 cm, 10 cm × 10 cm, 20 cm × 20 cm, and 30 cm × 30 cm for all available energy and was within ± 2 mm. Dosimetric leaf gap value for the multi‑leaf collimator was measured with 0.125 cc ionization chamber and values are −0.853 mm, −1.106 mm, −1.097 mm, −0.765 mm, and −1.005 mm for energies 6 MV, 10 MV, 15 MV, 6 flattening filter free (FFF), and 10 FFF, respectively. Conclusions: All electrical, mechanical, dosimetric, and safety measurement were found to be within permissible limits. Before clinical use, the beam data are crosschecked with point dosimetry, portal dosimetry, and MapCHECK two‑dimensional detector array and results are within tolerance.

Dibrugarh University (IN), Assam Medical College (IN)
Affordable and clean energy
Openalex Percentile: Top 42%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.