Ultrasonographic Venous Abnormalities in CEAP C1 Patients

Objective: The study aimed to investigate the ultrasonographic venous abnormalities in CEAP C1 patients and explore the relationship between venous abnormalities, vessel diameters, and patients’ baseline characteristics. Methods: We prospectively collected data from patients with lower limb chronic venous disease, CEAP C1 classification, who underwent Doppler ultrasound at our institution between December 2022 and May 2023. Demographic data, including age, sex, weight, height, underlying non-communicable diseases (NCDs), including diabetes, hypertension, and dyslipidemia, long-standing hours per day, and vessel diameters, were collected. Patients were divided into reflux and non-reflux groups. The association between venous abnormalities, vessel diameters, and patients’ baseline characteristics was analyzed by using correlation tests. Results: There were 94 participants, mean 44.9 (+ 13.4 SD) years. Eighty-eight (93.6%) were female. Eleven participants had 1 symptomatic limb; thus, a total of 177 limbs were assessed. In the 177 limbs assessed, refluxes were found in 25 (14.1%) limbs, including 2 (1.1%) limbs in deep veins, 11 (6.2%) limbs in superficial veins, 8 (4.5%) limbs in perforators, and 4 (2.3%) limbs in both great saphenous veins (GSV) and perforators. Perforator diameter ≥1.8 mm had a significant relationship with reflux ( p = .017), while GSV diameter and patients’ baseline characteristics had no relationship with venous reflux. No thrombosis or short saphenous vein abnormalities were shown in this study. Conclusions: Venous abnormalities were found in 14.1% of our CEAP C1 limbs. All were refluxes. Almost all of the refluxes occurred in superficial veins and/or perforators. There were no thromboses or abnormalities in the short saphenous vein. Perforator diameter ≥1.8 mm had a significant relationship with reflux ( p = .017). Short saphenous vein examinations and the augmentation test in perforator veins with a diameter less than 1.8 mm can be omitted from the screening protocol for CEAP C1 patients to reduce examination time.

Authors

Institutions

Publication Details

Journal
Journal for Vascular Ultrasound
Published
2026-02-22
DOI
https://doi.org/10.1177/15443167261421212
Primary Topic
Diagnosis and Treatment of Venous Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasonographic Venous Abnormalities in CEAP C1 Patients

Trakarn Chaivanit, Watanya Jaidee, Teetawat Jearsirikul, Sornsupha Limchareon et al.
Journal for Vascular Ultrasound
Diagnosis and Treatment of Venous Diseases
article

Ultrasonographic Venous Abnormalities in CEAP C1 Patients

Trakarn Chaivanit, Watanya Jaidee, Teetawat Jearsirikul, Sornsupha Limchareon, Thanchanok Nanthanasub, Sorawat Ketkaewmanee
article en

Abstract

Objective: The study aimed to investigate the ultrasonographic venous abnormalities in CEAP C1 patients and explore the relationship between venous abnormalities, vessel diameters, and patients’ baseline characteristics. Methods: We prospectively collected data from patients with lower limb chronic venous disease, CEAP C1 classification, who underwent Doppler ultrasound at our institution between December 2022 and May 2023. Demographic data, including age, sex, weight, height, underlying non-communicable diseases (NCDs), including diabetes, hypertension, and dyslipidemia, long-standing hours per day, and vessel diameters, were collected. Patients were divided into reflux and non-reflux groups. The association between venous abnormalities, vessel diameters, and patients’ baseline characteristics was analyzed by using correlation tests. Results: There were 94 participants, mean 44.9 (+ 13.4 SD) years. Eighty-eight (93.6%) were female. Eleven participants had 1 symptomatic limb; thus, a total of 177 limbs were assessed. In the 177 limbs assessed, refluxes were found in 25 (14.1%) limbs, including 2 (1.1%) limbs in deep veins, 11 (6.2%) limbs in superficial veins, 8 (4.5%) limbs in perforators, and 4 (2.3%) limbs in both great saphenous veins (GSV) and perforators. Perforator diameter ≥1.8 mm had a significant relationship with reflux ( p = .017), while GSV diameter and patients’ baseline characteristics had no relationship with venous reflux. No thrombosis or short saphenous vein abnormalities were shown in this study. Conclusions: Venous abnormalities were found in 14.1% of our CEAP C1 limbs. All were refluxes. Almost all of the refluxes occurred in superficial veins and/or perforators. There were no thromboses or abnormalities in the short saphenous vein. Perforator diameter ≥1.8 mm had a significant relationship with reflux ( p = .017). Short saphenous vein examinations and the augmentation test in perforator veins with a diameter less than 1.8 mm can be omitted from the screening protocol for CEAP C1 patients to reduce examination time.

Journal for Vascular Ultrasound
Burapha University (TH)
Good health and well-being
Openalex Percentile: Top 47%
Diagnosis and Treatment of Venous Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.