The mechanics of the Less In More Out artificial heart: Modeling fabric-based soft robotic devices

• Computational model of a fabric soft artificial heart benchmarked with experiments • Model resolves deformation, internal stress, buckling, and strain paths in the device • Fewer pouches increase stroke volume but elevate peak stresses and reduce fatigue life • Heat-sealed seams and edge buckling govern durability-limiting stress concentrations • In silico informed design changes reduce peak stress by 10% without loss of output Recently, the Less In More Out device, a fluidically actuated soft total artificial heart was proposed. This device uses arrays of pouch motors to achieve a positive fluidic lever when pneumatically actuated against physiological hemodynamic conditions. Extensive experimental characterization demonstrated its potential; however, experiments alone cannot resolve the internal mechanical fields that govern device durability and performance. Here, we develop a computational framework to investigate intrinsic device mechanics, such as stress concentrations, strain paths, and fatigue life, and to explore targeted design modifications that improve durability and efficiency. We show that our model reproduces the nonlinear deformation and pressure–volume relationships measured experimentally under varying hemodynamic conditions. Across designs, devices with fewer pouches deliver higher stroke volumes but exhibit up to 50% higher peak von Mises stresses, which reduces their fatigue life. Our simulations further identify heat-sealed seams and buckling regions as durability-limiting features. As a proof of concept, we vary the valve support aspect ratio and relative endocardial-epicardial pouch fabric compliance, reducing the peak von Mises stress by ∼ 10% while maintaining identical physiological outputs and improving mechanical efficiency. Overall, our framework enables detailed evaluation of stress hotspots, buckling, and fatigue life, and offers a foundation for optimizing artificial hearts and other fluidically actuated fabric-based soft robotic devices.

Authors

Institutions

Publication Details

Journal
Journal of the Mechanics and Physics of Solids
Published
2026-02-22
DOI
https://doi.org/10.1016/j.jmps.2026.106565
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The mechanics of the Less In More Out artificial heart: Modeling fabric-based soft robotic devices

Mathias Peirlinck, Maziar Arfaee, Marin Lauber
Journal of the Mechanics and Physics of Solids
Soft Robotics and Applications
article

The mechanics of the Less In More Out artificial heart: Modeling fabric-based soft robotic devices

Mathias Peirlinck, Maziar Arfaee, Marin Lauber
article en

Abstract

• Computational model of a fabric soft artificial heart benchmarked with experiments • Model resolves deformation, internal stress, buckling, and strain paths in the device • Fewer pouches increase stroke volume but elevate peak stresses and reduce fatigue life • Heat-sealed seams and edge buckling govern durability-limiting stress concentrations • In silico informed design changes reduce peak stress by 10% without loss of output Recently, the Less In More Out device, a fluidically actuated soft total artificial heart was proposed. This device uses arrays of pouch motors to achieve a positive fluidic lever when pneumatically actuated against physiological hemodynamic conditions. Extensive experimental characterization demonstrated its potential; however, experiments alone cannot resolve the internal mechanical fields that govern device durability and performance. Here, we develop a computational framework to investigate intrinsic device mechanics, such as stress concentrations, strain paths, and fatigue life, and to explore targeted design modifications that improve durability and efficiency. We show that our model reproduces the nonlinear deformation and pressure–volume relationships measured experimentally under varying hemodynamic conditions. Across designs, devices with fewer pouches deliver higher stroke volumes but exhibit up to 50% higher peak von Mises stresses, which reduces their fatigue life. Our simulations further identify heat-sealed seams and buckling regions as durability-limiting features. As a proof of concept, we vary the valve support aspect ratio and relative endocardial-epicardial pouch fabric compliance, reducing the peak von Mises stress by ∼ 10% while maintaining identical physiological outputs and improving mechanical efficiency. Overall, our framework enables detailed evaluation of stress hotspots, buckling, and fatigue life, and offers a foundation for optimizing artificial hearts and other fluidically actuated fabric-based soft robotic devices.

Journal of the Mechanics and Physics of SolidsVol. 212
Erasmus MC (NL), Institute for Atomic and Molecular Physics (NL), Erasmus University Rotterdam (NL), Delft University of Technology (NL)
Openalex Percentile: Top 48%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines