Exploring the potential of β-Cyclodextrin@Ti3C2Tx MXene in electrochemical chiral recognition of tyrosine enantiomers

An electrochemical chiral sensor based on β-cyclodextrin@Ti3C2Tx MXene/screen printed carbon electrode (β-CD@MXene/SPCE) was developed for the determination of D- and L-tyrosine enantiomers for the first time. Morphological characterization of the material (β-CD@MXene) was performed using Field Emission-Scanning Electron Microscopy (FE-SEM) and Transmission Electron Microscopy (TEM) imaging, while X-ray Diffraction (XRD) and Fourier Transform Infrared Spectroscopy (FTIR) confirmed the crystalline structure and interaction between MXene and β-CD in structural characterization. To evaluate the electrochemical characterization of the modified electrodes, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques were applied. To investigate the electrochemical behavior of the tested D- and L-amino acid enantiomers, CV and differential pulse voltammetry (DPV) techniques were conducted. Among the tested chiral species, only D- and L-tyrosine showed distinct voltammetric signals. To investigate the electrochemical behavior of D- and L-tyrosine, CV and DPV techniques were conducted revealing an increase in oxidation peak currents with the increasing tyrosine concentration levels. The voltammetric response of racemic D/L-tyrosine was also examined. For real sample analysis, human serum was used in chronoamperometric measurements (10–100 µM), yielding a linear response. The LOD and LOQ values were 3.15 µM and 9.45 µM, respectively, for D-tyrosine, and 4.68 µM and 14.05 µM, respectively, for L-tyrosine in human serum samples.

Authors

Institutions

Publication Details

Journal
Microchimica Acta
Published
2026-02-23
DOI
https://doi.org/10.1007/s00604-026-07874-2
Primary Topic
MXene and MAX Phase Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring the potential of β-Cyclodextrin@Ti3C2Tx MXene in electrochemical chiral recognition of tyrosine enantiomers

Erhan Zor, Serdar Akbayrak, Eda Gumus, Sevda Hasanova
Microchimica Acta
MXene and MAX Phase Materials
article

Exploring the potential of β-Cyclodextrin@Ti3C2Tx MXene in electrochemical chiral recognition of tyrosine enantiomers

Erhan Zor, Serdar Akbayrak, Eda Gumus, Sevda Hasanova
article en

Abstract

An electrochemical chiral sensor based on β-cyclodextrin@Ti3C2Tx MXene/screen printed carbon electrode (β-CD@MXene/SPCE) was developed for the determination of D- and L-tyrosine enantiomers for the first time. Morphological characterization of the material (β-CD@MXene) was performed using Field Emission-Scanning Electron Microscopy (FE-SEM) and Transmission Electron Microscopy (TEM) imaging, while X-ray Diffraction (XRD) and Fourier Transform Infrared Spectroscopy (FTIR) confirmed the crystalline structure and interaction between MXene and β-CD in structural characterization. To evaluate the electrochemical characterization of the modified electrodes, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques were applied. To investigate the electrochemical behavior of the tested D- and L-amino acid enantiomers, CV and differential pulse voltammetry (DPV) techniques were conducted. Among the tested chiral species, only D- and L-tyrosine showed distinct voltammetric signals. To investigate the electrochemical behavior of D- and L-tyrosine, CV and DPV techniques were conducted revealing an increase in oxidation peak currents with the increasing tyrosine concentration levels. The voltammetric response of racemic D/L-tyrosine was also examined. For real sample analysis, human serum was used in chronoamperometric measurements (10–100 µM), yielding a linear response. The LOD and LOQ values were 3.15 µM and 9.45 µM, respectively, for D-tyrosine, and 4.68 µM and 14.05 µM, respectively, for L-tyrosine in human serum samples.

Microchimica ActaVol. 193(3)
Necmettin Erbakan University (TR)
Türkiye Bilimler Akademisi
Openalex Percentile: Top 48%
MXene and MAX Phase Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.