Long-Term Outcomes of Mechanical Mitral Valve Replacement: A Comparison of Four Valve Types

<b>Background:</b> The choice of mechanical prosthesis for mitral valve replacement (MVR) is critical, yet data comparing long-term outcomes across different valve types are still needed. This study aimed to compare the long-term clinical and echocardiographic outcomes of four distinct mechanical mitral valve prostheses. <b>Methods:</b> We retrospectively analyzed 431 patients who underwent mechanical MVR between 2009 and 2022 with one of four valve types: Carbomedics (n = 112), Bicarbon (n = 176), ATS (n = 89), or On-X (n = 54). A competing risk regression model was used to identify predictors of a composite endpoint (valve thrombosis, reoperation, stroke, pulmonary embolism, and major bleeding), accounting for all-cause mortality. Longitudinal echocardiographic data were analyzed using linear mixed-effects models. <b>Results:</b> The median follow-up was 62 months. The cumulative incidence of the composite endpoint at 10 years was 14% for the On-X valve, 12% for the Bicarbon valve, 9.5% for the Carbomedics valve, and 7% for the ATS valve. After adjusting for confounders, the type of valve prosthesis was not significantly associated with the composite endpoint. Significant predictors of adverse events included coronary artery disease (Sub-distribution Hazard Ratio [SHR] 2.70, <i>p</i> = 0.023), peripheral artery disease (SHR 6.29, <i>p</i> = 0.007), and smaller valve size (SHR 0.87, <i>p</i> = 0.037). No significant difference in overall survival was observed between the groups (log-rank <i>p</i> = 0.904). All valve types were associated with favorable LV remodeling. The Carbomedics group showed the greatest reduction in left ventricular end-diastolic diameter, likely reflecting regression to the mean given the larger baseline ventricular dimensions in this group. <b>Conclusions:</b> The type of mechanical mitral valve did not significantly influence long-term thromboembolic and bleeding events or overall survival. Patient-specific factors and valve size were the primary determinants of adverse outcomes. The observed differences in ventricular remodeling may warrant further investigation.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-02-21
DOI
https://doi.org/10.3390/jcm15041633
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-Term Outcomes of Mechanical Mitral Valve Replacement: A Comparison of Four Valve Types

Mostafa A. Shalaby, Monirah Abdulrahman Albabtain, Huda Ismail, Fatimah Alhijab et al.
Journal of Clinical Medicine
Cardiac Valve Diseases and Treatments
article

Long-Term Outcomes of Mechanical Mitral Valve Replacement: A Comparison of Four Valve Types

Mostafa A. Shalaby, Monirah Abdulrahman Albabtain, Huda Ismail, Fatimah Alhijab, Musab Kiddo, Khaled Alotaibi, Amr A. Arafat, Saud Alshehri, Ismail M. Alnaggar, Rwan Alghamdi
article en

Abstract

<b>Background:</b> The choice of mechanical prosthesis for mitral valve replacement (MVR) is critical, yet data comparing long-term outcomes across different valve types are still needed. This study aimed to compare the long-term clinical and echocardiographic outcomes of four distinct mechanical mitral valve prostheses. <b>Methods:</b> We retrospectively analyzed 431 patients who underwent mechanical MVR between 2009 and 2022 with one of four valve types: Carbomedics (n = 112), Bicarbon (n = 176), ATS (n = 89), or On-X (n = 54). A competing risk regression model was used to identify predictors of a composite endpoint (valve thrombosis, reoperation, stroke, pulmonary embolism, and major bleeding), accounting for all-cause mortality. Longitudinal echocardiographic data were analyzed using linear mixed-effects models. <b>Results:</b> The median follow-up was 62 months. The cumulative incidence of the composite endpoint at 10 years was 14% for the On-X valve, 12% for the Bicarbon valve, 9.5% for the Carbomedics valve, and 7% for the ATS valve. After adjusting for confounders, the type of valve prosthesis was not significantly associated with the composite endpoint. Significant predictors of adverse events included coronary artery disease (Sub-distribution Hazard Ratio [SHR] 2.70, <i>p</i> = 0.023), peripheral artery disease (SHR 6.29, <i>p</i> = 0.007), and smaller valve size (SHR 0.87, <i>p</i> = 0.037). No significant difference in overall survival was observed between the groups (log-rank <i>p</i> = 0.904). All valve types were associated with favorable LV remodeling. The Carbomedics group showed the greatest reduction in left ventricular end-diastolic diameter, likely reflecting regression to the mean given the larger baseline ventricular dimensions in this group. <b>Conclusions:</b> The type of mechanical mitral valve did not significantly influence long-term thromboembolic and bleeding events or overall survival. Patient-specific factors and valve size were the primary determinants of adverse outcomes. The observed differences in ventricular remodeling may warrant further investigation.

Journal of Clinical MedicineVol. 15(4)
Ministry of Defence (GB), Prince Sultan University (SA), Cairo University (EG)
Good health and well-being
Openalex Percentile: Top 51%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.