ISCEV extended protocol for the photoreceptor directed ERG using full-field silent substitution stimuli

The International Society for Clinical Electrophysiology of Vision (ISCEV) Standard for full-field electroretinography (ERG) describes a minimum procedure, but encourages more extensive testing. This ISCEV extended protocol describes an extension to the full-field ERG Standard, namely the ERG responses to silent substitution stimuli that are directed at the response modulation of single photoreceptor types. The method can be used to detect selective defects in distinct photoreceptor types and post-receptoral retinal pathways. This document, based on existing literature, provides protocols for recording and analyzing the responses to a single class of photoreceptor directed stimuli. For each photoreceptor type (rods, L-, M- and S-cones), optimal luminance conditions and temporal frequencies for Ganzfeld recordings are provided. The exact stimulus conditions depend on the spectral properties of the stimulator. An accompanying technical report describes an app that is meant to provide support in calculating stimuli for individual stimulators.

Authors

Institutions

Publication Details

Journal
Documenta Ophthalmologica
Published
2026-02-22
DOI
https://doi.org/10.1007/s10633-026-10087-w
Primary Topic
Retinal Development and Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ISCEV extended protocol for the photoreceptor directed ERG using full-field silent substitution stimuli

Andrew J. Zele, N Parry, Anthony G. Robson, J.Jason McAnany et al.
Documenta Ophthalmologica
Retinal Development and Disorders
article

ISCEV extended protocol for the photoreceptor directed ERG using full-field silent substitution stimuli

Andrew J. Zele, N Parry, Anthony G. Robson, J.Jason McAnany, Jan Kremers, Beatrix Feigl, Balázs Vince Nagy, Omar A. Mahroo, Mirella T.S. Barboni, Cord Huchzermeyer
article en

Abstract

The International Society for Clinical Electrophysiology of Vision (ISCEV) Standard for full-field electroretinography (ERG) describes a minimum procedure, but encourages more extensive testing. This ISCEV extended protocol describes an extension to the full-field ERG Standard, namely the ERG responses to silent substitution stimuli that are directed at the response modulation of single photoreceptor types. The method can be used to detect selective defects in distinct photoreceptor types and post-receptoral retinal pathways. This document, based on existing literature, provides protocols for recording and analyzing the responses to a single class of photoreceptor directed stimuli. For each photoreceptor type (rods, L-, M- and S-cones), optimal luminance conditions and temporal frequencies for Ganzfeld recordings are provided. The exact stimulus conditions depend on the spectral properties of the stimulator. An accompanying technical report describes an app that is meant to provide support in calculating stimuli for individual stimulators.

Documenta Ophthalmologica
Semmelweis University (HU), Queensland University of Technology (AU), Manchester Academic Health Science Centre (GB), Manchester Royal Eye Hospital (GB), University of Manchester (GB), Budapest University of Technology and Economics (HU), University of Illinois Chicago (US), Universitätsklinikum Erlangen (DE), Queensland Eye Institute (AU), Moorfields Eye Hospital (GB), University College London (GB)
Openalex Percentile: Top 46%
Retinal Development and Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ISCEV extended protocol for the photoreceptor directed ERG using full-field silent substitution stimuli — Andrew J. Zele, N Parry, et al. · Documenta Ophthalmologica (2026) | TGRS Research Map | TGRS