CBCT-Based Orthodontic Classification Using Commercial AI: Completeness and Accuracy in Independent Validation

<b>Background/Objectives</b>: Artificial intelligence (AI) tools for orthodontic diagnosis are increasingly used in clinical practice; however, there is limited evidence regarding their performance in CBCT-based assessments. In this study, we evaluated the diagnostic reliability of the Diagnocat platform for categorical orthodontic diagnoses obtained from CBCT examinations. <b>Methods</b>: Fifty-nine patients who underwent large-field CBCT (13 × 16 cm) and lateral cephalograms within 30 days were included, and CBCT scans were processed using Diagnocat (v1.0). The platform's categorical outputs-sagittal skeletal class, vertical facial pattern, overbite category, and Dental Angle class-were compared with manual cephalometric analyses performed by an experienced orthodontist (reference standard). Standard thresholds were used to convert reference continuous measurements into categorical variables. Missing or 'N/A' index test outputs were treated as diagnostic failures in accordance with STARD recommendations. Agreement was assessed via Cohen's kappa (κ), and the sensitivity, specificity, PPV, and NPV were calculated for angle classification. <b>Results</b>: The AI platform generated skeletal and vertical classifications in only 3/59 (5%) and 1/59 (1.7%) patients, respectively. Agreement was fair (κ = 0.324) for overbite categorization, and the Dental Angle class was provided for 34/59 (57.6%) patients. When "N/A" results were treated as diagnostic failures, the overall system usability was <10% for skeletal parameters. <b>Conclusions</b>: The platform demonstrated insufficient diagnostic reliability and failed to generate outputs for most patients. While the specificities for generated diagnoses were acceptable, the low data completeness rate renders the tool currently unsuitable for independent clinical decision-making.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-02-21
DOI
https://doi.org/10.3390/jcm15041637
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CBCT-Based Orthodontic Classification Using Commercial AI: Completeness and Accuracy in Independent Validation

Natalia Kazimierczak, Wojciech Kazimierczak, Nora Sultani, Szymon Krzykowski et al.
Journal of Clinical Medicine
Dental Radiography and Imaging
article

CBCT-Based Orthodontic Classification Using Commercial AI: Completeness and Accuracy in Independent Validation

Natalia Kazimierczak, Wojciech Kazimierczak, Nora Sultani, Szymon Krzykowski, Zbigniew Serafin
article en

Abstract

<b>Background/Objectives</b>: Artificial intelligence (AI) tools for orthodontic diagnosis are increasingly used in clinical practice; however, there is limited evidence regarding their performance in CBCT-based assessments. In this study, we evaluated the diagnostic reliability of the Diagnocat platform for categorical orthodontic diagnoses obtained from CBCT examinations. <b>Methods</b>: Fifty-nine patients who underwent large-field CBCT (13 × 16 cm) and lateral cephalograms within 30 days were included, and CBCT scans were processed using Diagnocat (v1.0). The platform's categorical outputs-sagittal skeletal class, vertical facial pattern, overbite category, and Dental Angle class-were compared with manual cephalometric analyses performed by an experienced orthodontist (reference standard). Standard thresholds were used to convert reference continuous measurements into categorical variables. Missing or 'N/A' index test outputs were treated as diagnostic failures in accordance with STARD recommendations. Agreement was assessed via Cohen's kappa (κ), and the sensitivity, specificity, PPV, and NPV were calculated for angle classification. <b>Results</b>: The AI platform generated skeletal and vertical classifications in only 3/59 (5%) and 1/59 (1.7%) patients, respectively. Agreement was fair (κ = 0.324) for overbite categorization, and the Dental Angle class was provided for 34/59 (57.6%) patients. When "N/A" results were treated as diagnostic failures, the overall system usability was <10% for skeletal parameters. <b>Conclusions</b>: The platform demonstrated insufficient diagnostic reliability and failed to generate outputs for most patients. While the specificities for generated diagnoses were acceptable, the low data completeness rate renders the tool currently unsuitable for independent clinical decision-making.

Journal of Clinical MedicineVol. 15(4)
Bydgoszcz University of Science and Technology (PL), Kazimierz Wielki University in Bydgoszcz (PL), Nicolaus Copernicus University (PL), AGH University of Krakow (PL)
Peace, Justice and strong institutions
Openalex Percentile: Top 49%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.