Experimental Characterisation of Differently Composed Thrombus Entities with Spectral-Detector-CT

<b>Background/Objectives</b>: Thrombus composition influences the success of endovascular therapy in stroke, but conventional CT is limited in determining it. Spectral-detector-CT (SDCT) can apply material-decomposition and virtual monoenergetic (MonoE) imaging, which may provide a way to gain information on thrombus composition. This experimental study aimed to evaluate the differentiability of heterogeneous thrombi with variable red blood cell (RBC) content using SDCT. <b>Methods</b>: Ten thrombus entities with different compositions on RBC and plasma, thus fibrin content, were manufactured (volumetric RBC%/Plasma% = 90/10; 80/20; 70/30; 60/40; 50/50; 40/60; 30/70; 20/80; 10/90; 5/95) and scanned in an SDCT. Conventional Hounsfield-unit (HU) values, spectral electron density (ED), effective atomic number (Z-effective) and HU in MonoE maps ranging from 40- to 200 keV were evaluated for thrombus differentiation. <b>Results</b>: Conventional HU increased with RBC content, allowing us to differentiate the entities (<i>p</i> < 0.001). ED values also increased with RBC content and allowed for differentiation too (<i>p</i> < 0.001). Z-effective values showed no differences among the different entities (<i>p</i> > 0.05). Regarding the mass-attenuation curves from 40 to 200 keV the different thrombi showed a similar curve progression with highest HU values at 40 and lowest at 200 keV. The thrombi could be distinguished overall at each monoenergetic level by HU (<i>p</i> < 0.001 for each level). The absolute decrease in HU between 40 and 200 keV was thereby not significantly different between the different entities, but the relative decrease was, as it was more pronounced in thrombi with lower RBC content (<i>p</i> < 0.001). <b>Conclusions</b>: Spectral CT enables differentiation between thrombi with different RBC and fibrin contents by means of ED or analysis of the mass-attenuation curve. This offers alternative possibilities that go beyond characterisation based on CT-density alone. The additional inclusion of spectral parameters in thrombus diagnostics could therefore improve diagnosis and treatment.

Authors

Institutions

Publication Details

Journal
Neurology International
Published
2026-02-21
DOI
https://doi.org/10.3390/neurolint18020038
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Characterisation of Differently Composed Thrombus Entities with Spectral-Detector-CT

Lars-Patrick Schmill, Patrick Langguth, Naomi Jean Larsen, Agreen Horr et al.
Neurology International
Advanced X-ray and CT Imaging
article

Experimental Characterisation of Differently Composed Thrombus Entities with Spectral-Detector-CT

Lars-Patrick Schmill, Patrick Langguth, Naomi Jean Larsen, Agreen Horr, Julian Andersson, Jens Trentmann, Schekeb Aludin, Svea Seehafer, Carmen Wolf, Bodo Kurz, Olav Jansen
article en

Abstract

<b>Background/Objectives</b>: Thrombus composition influences the success of endovascular therapy in stroke, but conventional CT is limited in determining it. Spectral-detector-CT (SDCT) can apply material-decomposition and virtual monoenergetic (MonoE) imaging, which may provide a way to gain information on thrombus composition. This experimental study aimed to evaluate the differentiability of heterogeneous thrombi with variable red blood cell (RBC) content using SDCT. <b>Methods</b>: Ten thrombus entities with different compositions on RBC and plasma, thus fibrin content, were manufactured (volumetric RBC%/Plasma% = 90/10; 80/20; 70/30; 60/40; 50/50; 40/60; 30/70; 20/80; 10/90; 5/95) and scanned in an SDCT. Conventional Hounsfield-unit (HU) values, spectral electron density (ED), effective atomic number (Z-effective) and HU in MonoE maps ranging from 40- to 200 keV were evaluated for thrombus differentiation. <b>Results</b>: Conventional HU increased with RBC content, allowing us to differentiate the entities (<i>p</i> < 0.001). ED values also increased with RBC content and allowed for differentiation too (<i>p</i> < 0.001). Z-effective values showed no differences among the different entities (<i>p</i> > 0.05). Regarding the mass-attenuation curves from 40 to 200 keV the different thrombi showed a similar curve progression with highest HU values at 40 and lowest at 200 keV. The thrombi could be distinguished overall at each monoenergetic level by HU (<i>p</i> < 0.001 for each level). The absolute decrease in HU between 40 and 200 keV was thereby not significantly different between the different entities, but the relative decrease was, as it was more pronounced in thrombi with lower RBC content (<i>p</i> < 0.001). <b>Conclusions</b>: Spectral CT enables differentiation between thrombi with different RBC and fibrin contents by means of ED or analysis of the mass-attenuation curve. This offers alternative possibilities that go beyond characterisation based on CT-density alone. The additional inclusion of spectral parameters in thrombus diagnostics could therefore improve diagnosis and treatment.

Neurology InternationalVol. 18(2)
Christian-Albrechts-Universität zu Kiel (DE), University Hospital Schleswig-Holstein (DE), University of Lübeck (DE)
Openalex Percentile: Top 48%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.