Thermal Injury Leading to Myocardial Perforation During Cavotricuspid Isthmus Ablation: A Case Report

Objective:Rare coexistence of disease or pathology Background:Radiofrequency ablation is an established and safe treatment for atrial arrhythmias, including atrial fibrillation and atrial flutter.However, rare complications related to thermal myocardial injury, such as steam pop, can occur and occasionally result in life-threatening events.This report describes the case of a 70-year-old man who developed myocardial perforation and hemopericardium associated with a steam pop during cavo-tricuspid isthmus (CTI) ablation. Case Report:A 70-year-old man with a 6-month history of palpitations and exertional dyspnea underwent catheter ablation for atrial fibrillation and atrial flutter.Pulmonary vein isolation was first performed using a cryo-balloon, followed by cavo-tricuspid isthmus ablation with a non-irrigated IntellaTip MIFI XP catheter (Boston Scientific) at 70 W and 65C under fluoroscopic guidance.During the fourth radiofrequency application, the operator perceived a sudden tactile impulse ("pop") at the catheter tip, without any significant preceding impedance changes.Several minutes later, echocardiography revealed a large pericardial effusion.Immediate pericardial drainage evacuated 1200 mL of blood; however, bleeding persisted, necessitating emergency thoracotomy.A 1-cm myocardial rupture was identified between the inferior vena cava and the tricuspid annulus, consistent with a thermally induced myocardial injury.The patient recovered uneventfully and was discharged on postoperative day 16. Conclusions:This case demonstrates that a steam pop and subsequent cardiac rupture can occur abruptly during cavo-tricuspid isthmus ablation, even in the absence of significant temperature or impedance fluctuations up to onset.Clinicians should be aware that generator parameters do not necessarily exclude the risk of severe complications during radiofrequency ablation.

Authors

Institutions

Publication Details

Journal
American Journal of Case Reports
Published
2026-02-21
DOI
https://doi.org/10.12659/ajcr.951012
Primary Topic
Trauma Management and Diagnosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Injury Leading to Myocardial Perforation During Cavotricuspid Isthmus Ablation: A Case Report

Masahiro Mutoh, Kohei Sawasaki, Natsuko Hosoya
American Journal of Case Reports
Trauma Management and Diagnosis
article

Thermal Injury Leading to Myocardial Perforation During Cavotricuspid Isthmus Ablation: A Case Report

Masahiro Mutoh, Kohei Sawasaki, Natsuko Hosoya
article en

Abstract

Objective:Rare coexistence of disease or pathology Background:Radiofrequency ablation is an established and safe treatment for atrial arrhythmias, including atrial fibrillation and atrial flutter.However, rare complications related to thermal myocardial injury, such as steam pop, can occur and occasionally result in life-threatening events.This report describes the case of a 70-year-old man who developed myocardial perforation and hemopericardium associated with a steam pop during cavo-tricuspid isthmus (CTI) ablation. Case Report:A 70-year-old man with a 6-month history of palpitations and exertional dyspnea underwent catheter ablation for atrial fibrillation and atrial flutter.Pulmonary vein isolation was first performed using a cryo-balloon, followed by cavo-tricuspid isthmus ablation with a non-irrigated IntellaTip MIFI XP catheter (Boston Scientific) at 70 W and 65C under fluoroscopic guidance.During the fourth radiofrequency application, the operator perceived a sudden tactile impulse ("pop") at the catheter tip, without any significant preceding impedance changes.Several minutes later, echocardiography revealed a large pericardial effusion.Immediate pericardial drainage evacuated 1200 mL of blood; however, bleeding persisted, necessitating emergency thoracotomy.A 1-cm myocardial rupture was identified between the inferior vena cava and the tricuspid annulus, consistent with a thermally induced myocardial injury.The patient recovered uneventfully and was discharged on postoperative day 16. Conclusions:This case demonstrates that a steam pop and subsequent cardiac rupture can occur abruptly during cavo-tricuspid isthmus ablation, even in the absence of significant temperature or impedance fluctuations up to onset.Clinicians should be aware that generator parameters do not necessarily exclude the risk of severe complications during radiofrequency ablation.

American Journal of Case ReportsVol. 27
Hamamatsu Medical Center (JP)
Good health and well-being
Openalex Percentile: Top 48%
Trauma Management and Diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Thermal Injury Leading to Myocardial Perforation During Cavotricuspid Isthmus Ablation: A Case Report — Masahiro Mutoh, Kohei Sawasaki, et al. · American Journal of Case Reports (2026) | TGRS Research Map | TGRS