Metrological setup for accurate determination of passive radiative cooling power

Passive radiative cooling (PRC) enables heat rejection to the cold sky through the atmospheric transparency window and has attracted increasing attention as a power-free cooling strategy. However, reported cooling performances remain difficult to compare and often unreliable, primarily due to the lack of metrologically sound measurement methods and quantitative uncertainty assessment. In this work, a fluid-based calorimetric apparatus is designed according to a traceable metrological framework for the accurate determination of PRC cooling power. The system offers a compact panel-like geometry with uniform liquid flow distribution and employs high-sensitivity, SI-traceable sensors. In particular, the temperature difference between inlet and outlet water is measured directly using a calibrated multi junction differential thermocouple (thermopile) achieving an expanded uncertainty of just 12.4 mK, allowing to reliably measure also small temperature differences between the panel outlet and inlet ports. Together with a calibrated flow-rate measurement and a full uncertainty budget, the proposed design allows relative uncertainties consistently below 10% over almost the complete range of power densities relevant to PRC materials. Even at moderate fluxes, and in the presence of non-radiative heat transfer contributions, the setup achieves a significant improvement over the measurement uncertainties reported in the literature for comparable setups. These results and comparative analysis demonstrate that metrology-driven design is essential for reliable PRC performance assessment and provide a robust benchmark for future material development and system-level studies. • SI-traceable metrology enables full uncertainty budgeting of PRC testing device. • Calorimetric vessel with uniform liquid flow enables PRC cooling power measurement. • Calorimetry mimics real-world use with a compact form factor to balance response time. • Thermopiles outperform thermistors, reaching an expanded uncertainty of 12.4 mK. • Improved measurement uncertainty in PRC cooling power determination.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2026-02-21
DOI
https://doi.org/10.1016/j.applthermaleng.2026.130363
Primary Topic
Thermal Radiation and Cooling Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metrological setup for accurate determination of passive radiative cooling power

D. Giraudi, F. Girard, L. Pattelli, G. Lopardo et al.
Applied Thermal Engineering
Thermal Radiation and Cooling Technologies
article

Metrological setup for accurate determination of passive radiative cooling power

D. Giraudi, F. Girard, L. Pattelli, G. Lopardo, M. Florio, G. Braccialarghe, F. Santoro, F. Bertiglia
article en

Abstract

Passive radiative cooling (PRC) enables heat rejection to the cold sky through the atmospheric transparency window and has attracted increasing attention as a power-free cooling strategy. However, reported cooling performances remain difficult to compare and often unreliable, primarily due to the lack of metrologically sound measurement methods and quantitative uncertainty assessment. In this work, a fluid-based calorimetric apparatus is designed according to a traceable metrological framework for the accurate determination of PRC cooling power. The system offers a compact panel-like geometry with uniform liquid flow distribution and employs high-sensitivity, SI-traceable sensors. In particular, the temperature difference between inlet and outlet water is measured directly using a calibrated multi junction differential thermocouple (thermopile) achieving an expanded uncertainty of just 12.4 mK, allowing to reliably measure also small temperature differences between the panel outlet and inlet ports. Together with a calibrated flow-rate measurement and a full uncertainty budget, the proposed design allows relative uncertainties consistently below 10% over almost the complete range of power densities relevant to PRC materials. Even at moderate fluxes, and in the presence of non-radiative heat transfer contributions, the setup achieves a significant improvement over the measurement uncertainties reported in the literature for comparable setups. These results and comparative analysis demonstrate that metrology-driven design is essential for reliable PRC performance assessment and provide a robust benchmark for future material development and system-level studies. • SI-traceable metrology enables full uncertainty budgeting of PRC testing device. • Calorimetric vessel with uniform liquid flow enables PRC cooling power measurement. • Calorimetry mimics real-world use with a compact form factor to balance response time. • Thermopiles outperform thermistors, reaching an expanded uncertainty of 12.4 mK. • Improved measurement uncertainty in PRC cooling power determination.

Applied Thermal EngineeringVol. 292
Istituto Nazionale di Ricerca Metrologica (IT)
Affordable and clean energy
Openalex Percentile: Top 48%
Thermal Radiation and Cooling Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.