Implementation of an Intraoperative Augmented Reality Environment for Custom-Made Partial Pelvis Replacements—A Proof of Concept and Initial Results

<b>Background</b>: The use of augmented reality (AR) in orthopaedics is growing rapidly but is mainly limited to pre-operative planning and teaching. This study is one of the first to describe the intraoperative application within revision arthroplasty for the positioning of customised partial pelvic replacements. <b>Methods</b>: In a proof-of-concept study an AR environment was used during surgery in 11 cases to enhance implant positioning. Postoperatively, a voxel-based CT deviation analysis was carried out to determine the COR deviation and the cup plane deviation angle. Additionally, digital implant superimposition was conducted. <b>Results</b>: Implantation was possible in all cases with a mean COR deviation vector of 4.2 (SD 2.5; 1.2-9.3) mm and a cup plane deviation angle of 4.4 (SD 2.5; 0.7-8.1)°. The implant analysis showed a superimposition of 0.69 (SD 0.15; 0.38-0.88) (Dice-Score calculation). <b>Conclusions</b>: This study is able to report promising results for AR in orthopaedic surgery, showing improved intraoperative feedback in complex operations, resulting in increased accuracy. However, the integration of AR poses a new challenge to the surgical team, especially because the AR users are facing a significantly increased level of intraoperative stress. Further development of this auspicious tool, as well as a conceivable combination with navigation, is necessary to facilitate broader usage.

Authors

Institutions

Publication Details

Journal
Journal of Personalized Medicine
Published
2026-02-21
DOI
https://doi.org/10.3390/jpm16020124
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of an Intraoperative Augmented Reality Environment for Custom-Made Partial Pelvis Replacements—A Proof of Concept and Initial Results

Arne Streitbuerger, Jendrik Hardes, Yannik Hanusrichter, Sven Frieler et al.
Journal of Personalized Medicine
Surgical Simulation and Training
article

Implementation of an Intraoperative Augmented Reality Environment for Custom-Made Partial Pelvis Replacements—A Proof of Concept and Initial Results

Arne Streitbuerger, Jendrik Hardes, Yannik Hanusrichter, Sven Frieler, Martin Weßling, Carsten Gebert, Marcel Dudda, Lee Jeys
article en

Abstract

<b>Background</b>: The use of augmented reality (AR) in orthopaedics is growing rapidly but is mainly limited to pre-operative planning and teaching. This study is one of the first to describe the intraoperative application within revision arthroplasty for the positioning of customised partial pelvic replacements. <b>Methods</b>: In a proof-of-concept study an AR environment was used during surgery in 11 cases to enhance implant positioning. Postoperatively, a voxel-based CT deviation analysis was carried out to determine the COR deviation and the cup plane deviation angle. Additionally, digital implant superimposition was conducted. <b>Results</b>: Implantation was possible in all cases with a mean COR deviation vector of 4.2 (SD 2.5; 1.2-9.3) mm and a cup plane deviation angle of 4.4 (SD 2.5; 0.7-8.1)°. The implant analysis showed a superimposition of 0.69 (SD 0.15; 0.38-0.88) (Dice-Score calculation). <b>Conclusions</b>: This study is able to report promising results for AR in orthopaedic surgery, showing improved intraoperative feedback in complex operations, resulting in increased accuracy. However, the integration of AR poses a new challenge to the surgical team, especially because the AR users are facing a significantly increased level of intraoperative stress. Further development of this auspicious tool, as well as a conceivable combination with navigation, is necessary to facilitate broader usage.

Journal of Personalized MedicineVol. 16(2)
Aston University (GB), Royal Orthopaedic Hospital (GB), Evangelische Stiftung Volmarstein (DE), University Hospital Münster (DE), Essen University Hospital (DE), BG University Hospital Bergmannsheil Bochum (DE)
Openalex Percentile: Top 48%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.