Practical Considerations for Continuous Monitoring of Hexavalent Chromium in Wastewater Using a Microbial Fuel Cell Biosensor: Biosensor Fabrication, Sample Pretreatment, and Bacterial Community Analysis

Hexavalent chromium (Cr(VI)) is a high-priority environmental pollutant due to its strong oxidizing properties, which cause DNA damage and other severe health effects. Conventional detection methods are often costly and lack real-time monitoring capabilities, creating a strong demand for cost-effective, real-time biosensors that meet industrial requirements. In this study, we developed a novel biosensor for continuous Cr(VI) monitoring using a single-chamber microbial fuel cell (MFC). The biological element is an engineered <i>Escherichia coli</i> strain (<i>ChrA-ChrB-E. coli</i>), constructed by introducing Cr(VI)-resistant (<i>ChrA</i>) and Cr(VI)-reducing (<i>ChrB</i>) genes. The presence of Cr(VI) affects bacterial metabolism and electron transfer within the MFC, generating a measurable signal proportional to the contaminant's concentration. The biosensor demonstrated robust performance and characteristics. The recombinant strain retained functional activity after 450 days of storage at -20 °C. The system exhibited high sensitivity and excellent linearity (R<sup>2</sup> ≥ 0.999) across a broad Cr(VI) concentration range of 0.015-200 mg/L. During continuous monitoring of chrome tanning and electroplating wastewater, measurements deviated by less than 2.33% from the standard diphenylcarbazide (DPC) method; electroplating deviation was further reduced to -0.69% with EDTA pretreatment. In fishery water, the deviation was higher (-7.12%) due to dissolved oxygen (DO) interference but was reduced to -0.75% after mechanical stirring to remove DO. The biofilm bacterial community remained highly stable over six months in both wastewater types, with the inoculated <i>ChrA-ChrB-E. coli</i> strain maintaining dominance (>99.6%). These results substantiate the feasibility of using this biosensor for continuous, online, real-time detection of Cr(VI) in actual wastewater environments.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-02-21
DOI
https://doi.org/10.3390/bios16020130
Primary Topic
Microbial Fuel Cells and Bioremediation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Practical Considerations for Continuous Monitoring of Hexavalent Chromium in Wastewater Using a Microbial Fuel Cell Biosensor: Biosensor Fabrication, Sample Pretreatment, and Bacterial Community Analysis

Guey‐Horng Wang, Chiu-Yu Cheng, Ying-Chien Chung
Biosensors
Microbial Fuel Cells and Bioremediation
article

Practical Considerations for Continuous Monitoring of Hexavalent Chromium in Wastewater Using a Microbial Fuel Cell Biosensor: Biosensor Fabrication, Sample Pretreatment, and Bacterial Community Analysis

Guey‐Horng Wang, Chiu-Yu Cheng, Ying-Chien Chung
article en

Abstract

Hexavalent chromium (Cr(VI)) is a high-priority environmental pollutant due to its strong oxidizing properties, which cause DNA damage and other severe health effects. Conventional detection methods are often costly and lack real-time monitoring capabilities, creating a strong demand for cost-effective, real-time biosensors that meet industrial requirements. In this study, we developed a novel biosensor for continuous Cr(VI) monitoring using a single-chamber microbial fuel cell (MFC). The biological element is an engineered <i>Escherichia coli</i> strain (<i>ChrA-ChrB-E. coli</i>), constructed by introducing Cr(VI)-resistant (<i>ChrA</i>) and Cr(VI)-reducing (<i>ChrB</i>) genes. The presence of Cr(VI) affects bacterial metabolism and electron transfer within the MFC, generating a measurable signal proportional to the contaminant's concentration. The biosensor demonstrated robust performance and characteristics. The recombinant strain retained functional activity after 450 days of storage at -20 °C. The system exhibited high sensitivity and excellent linearity (R<sup>2</sup> ≥ 0.999) across a broad Cr(VI) concentration range of 0.015-200 mg/L. During continuous monitoring of chrome tanning and electroplating wastewater, measurements deviated by less than 2.33% from the standard diphenylcarbazide (DPC) method; electroplating deviation was further reduced to -0.69% with EDTA pretreatment. In fishery water, the deviation was higher (-7.12%) due to dissolved oxygen (DO) interference but was reduced to -0.75% after mechanical stirring to remove DO. The biofilm bacterial community remained highly stable over six months in both wastewater types, with the inoculated <i>ChrA-ChrB-E. coli</i> strain maintaining dominance (>99.6%). These results substantiate the feasibility of using this biosensor for continuous, online, real-time detection of Cr(VI) in actual wastewater environments.

BiosensorsVol. 16(2)
China University of Science and Technology (TW), Xiamen Medical College
National Science and Technology Council
Clean water and sanitation
Openalex Percentile: Top 55%
Microbial Fuel Cells and Bioremediation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.