Numerical Investigation of a Dual‐Mode Shape Memory Alloy Stent Enabling Secondary Expansion via Focused Ultrasound: A Potential Strategy for Correcting In‐Stent Restenosis

Coronary stent implantation is an invasive procedure performed to correct atherosclerosis. The aftermath of this procedure is identified with neointimal hyperplasia, which contributes to in‐stent restenosis (ISR), and thus remains a significant clinical challenge. This study introduces a novel, noninvasive conceptual approach for addressing ISR through the thermal activation of shape memory alloy (SMA) stent using focused ultrasound (FU) in a controlled manner to restore luminal patency. COMSOL Multiphysics and ABAQUS finite element software were employed to perform the numerical modeling to simulate the thermal and mechanical responses of the SMA stent integrated into the arterial wall. After 15 s of insonation, the temperature within the tissue layers rises from 37°C to 42.63°C. Surface temperature rise plot confirms that heat is directed at the target region (focal zone) with minimal heating effect to the surrounding tissues. Minor increases in stress development in both the stent and artery observed were within acceptable limits, which indicates mechanical integrity and a low chance of increasing mechanical damage via stretching to the tissue. This development offers a viable alternative to reintervention, providing precise, patient‐specific, and ultrasonically guided therapy for ISR.

Authors

Institutions

Publication Details

Journal
Advanced Engineering Materials
Published
2026-02-21
DOI
https://doi.org/10.1002/adem.202502037
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Investigation of a Dual‐Mode Shape Memory Alloy Stent Enabling Secondary Expansion via Focused Ultrasound: A Potential Strategy for Correcting In‐Stent Restenosis

Brian L. Davis, Stephen Asare, Josiah Owusu‐Danquah, Lucinda Duncan
Advanced Engineering Materials
Coronary Interventions and Diagnostics
article

Numerical Investigation of a Dual‐Mode Shape Memory Alloy Stent Enabling Secondary Expansion via Focused Ultrasound: A Potential Strategy for Correcting In‐Stent Restenosis

Brian L. Davis, Stephen Asare, Josiah Owusu‐Danquah, Lucinda Duncan
article en

Abstract

Coronary stent implantation is an invasive procedure performed to correct atherosclerosis. The aftermath of this procedure is identified with neointimal hyperplasia, which contributes to in‐stent restenosis (ISR), and thus remains a significant clinical challenge. This study introduces a novel, noninvasive conceptual approach for addressing ISR through the thermal activation of shape memory alloy (SMA) stent using focused ultrasound (FU) in a controlled manner to restore luminal patency. COMSOL Multiphysics and ABAQUS finite element software were employed to perform the numerical modeling to simulate the thermal and mechanical responses of the SMA stent integrated into the arterial wall. After 15 s of insonation, the temperature within the tissue layers rises from 37°C to 42.63°C. Surface temperature rise plot confirms that heat is directed at the target region (focal zone) with minimal heating effect to the surrounding tissues. Minor increases in stress development in both the stent and artery observed were within acceptable limits, which indicates mechanical integrity and a low chance of increasing mechanical damage via stretching to the tissue. This development offers a viable alternative to reintervention, providing precise, patient‐specific, and ultrasonically guided therapy for ISR.

Advanced Engineering MaterialsVol. 28(6)
Cleveland State University (US)
National Aeronautics and Space Administration, Cleveland State University, Nuclear Safety and Security Commission
Openalex Percentile: Top 48%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Numerical Investigation of a Dual‐Mode Shape Memory Alloy Stent Enabling Secondary Expansion via Focused Ultrasound: A Potential Strategy for Correcting In‐Stent Restenosis — Brian L. Davis, Stephen Asare, et al. · Advanced Engineering Materials (2026) | TGRS Research Map | TGRS