Comparative study of wavelet transform and Fourier domain filtering for medical image denoising

Image denoising is a crucial preprocessing step in medical imaging. While deep learning methods offer state-of-the-art performance, their computational complexity and data requirements can be prohibitive. Traditional transform-domain methods, particularly wavelet transforms, remain widely used due to their efficiency and interpretability. However, a comprehensive comparison of wavelet families and thresholding techniques for diverse medical noise types is lacking, and the relative performance of wavelet versus localized Fourier methods is not well established. Here, we conduct a two-part investigation. First, we evaluate eight wavelet families combined with twelve thresholding functions and four threshold selection rules on a CT image corrupted with Gaussian, Uniform, Poisson, and Salt-and-Pepper noise. Second, we compare the best wavelet configurations against a block-based Discrete Fourier Cosine Transform (DFCT) approach using overlapping blocks. Among wavelet methods, Biorthogonal Spline and Daubechies wavelets with adaptive thresholding (Smooth Garrote, SURE) performed best. However, the block-based DFCT method consistently outperformed all global DWT configurations across all noise types. DFCT achieved PSNR dB-values of [Formula: see text] (Gaussian), [Formula: see text] (uniform), [Formula: see text] (Poisson), and [Formula: see text] (salt-and-pepper), representing improvements of 4.63, 4.57, 6.25, and 5.07 dB respectively over the best wavelet results. In contrast to the common assumption that wavelet transforms are superior due to multi-resolution analysis, our results demonstrate that a block-based DFCT approach provides significantly better denoising performance across diverse noise types. These findings emphasize the importance of algorithmic selection based on processing methodology rather than solely on transform properties.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-21
DOI
https://doi.org/10.1038/s41598-026-40594-4
Primary Topic
Image and Signal Denoising Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative study of wavelet transform and Fourier domain filtering for medical image denoising

Bassam M. Mughalles, Ibrahim. G. H. Loqman, M. Ali Saif
Scientific Reports
Image and Signal Denoising Methods
article

Comparative study of wavelet transform and Fourier domain filtering for medical image denoising

Bassam M. Mughalles, Ibrahim. G. H. Loqman, M. Ali Saif
article en

Abstract

Image denoising is a crucial preprocessing step in medical imaging. While deep learning methods offer state-of-the-art performance, their computational complexity and data requirements can be prohibitive. Traditional transform-domain methods, particularly wavelet transforms, remain widely used due to their efficiency and interpretability. However, a comprehensive comparison of wavelet families and thresholding techniques for diverse medical noise types is lacking, and the relative performance of wavelet versus localized Fourier methods is not well established. Here, we conduct a two-part investigation. First, we evaluate eight wavelet families combined with twelve thresholding functions and four threshold selection rules on a CT image corrupted with Gaussian, Uniform, Poisson, and Salt-and-Pepper noise. Second, we compare the best wavelet configurations against a block-based Discrete Fourier Cosine Transform (DFCT) approach using overlapping blocks. Among wavelet methods, Biorthogonal Spline and Daubechies wavelets with adaptive thresholding (Smooth Garrote, SURE) performed best. However, the block-based DFCT method consistently outperformed all global DWT configurations across all noise types. DFCT achieved PSNR dB-values of [Formula: see text] (Gaussian), [Formula: see text] (uniform), [Formula: see text] (Poisson), and [Formula: see text] (salt-and-pepper), representing improvements of 4.63, 4.57, 6.25, and 5.07 dB respectively over the best wavelet results. In contrast to the common assumption that wavelet transforms are superior due to multi-resolution analysis, our results demonstrate that a block-based DFCT approach provides significantly better denoising performance across diverse noise types. These findings emphasize the importance of algorithmic selection based on processing methodology rather than solely on transform properties.

Scientific ReportsVol. 16(1)
Sana'a University (YE), Amran University (YE)
Openalex Percentile: Top 49%
Image and Signal Denoising Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.