Accuracy of four-dimensional (4D) flow magnetic resonance imaging (MRI) in quantifying aortic regurgitation: a comparison with two- dimensional (2D) MRI and echocardiography

Abstract Background Aortic regurgitation (AR) is a common valvular disorder that may occur as an isolated lesion or alongside congenital heart disease (CHD). While transthoracic echocardiography (TTE) remains the primary imaging modality for diagnosing and grading AR, cardiovascular magnetic resonance (CMR) is increasingly used for its high accuracy in quantifying ventricular volumes and function. Traditional CMR relies on Two-Dimensional (2D) phase-contrast (PC) sequences with flow assessment limited to predefined planes. In hcontrast, Four-Dimensional (4D) flow CMR offers comprehensive volumetric coverage, enabling retrospective blood flow analysis at any location. This prospective study of 44 subjects (29 with AR and 15 healthy controls) aims to evaluate the diagnostic performance of 4D flow CMR in assessing aortic valve AR and to compare its performance with 2D-PC MRI and TTE. Results In AR patients, left ventricular parameters were significantly increased. Aortic regurgitant fraction (RF) values did not differ significantly between 2 and 4D flow MRI measured at levels of aortic valve and pulmonary artery. RF at aortic valve level was significantly lower than at supra-valvular levels. The highest concordance between 4D flow MRI and TTE for AR grading occurred at the pulmonary artery level. Conclusion 4D flow MRI provides reliable estimation of AR, with measurement of aortic RF at the pulmonary artery level showing the strongest agreement with echocardiographic grading, while measurement at aortic valve level tends to underestimate severity. These findings support pulmonary artery level assessment as the preferred site for accurate AR evaluation.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2026-02-21
DOI
https://doi.org/10.1186/s43055-026-01701-7
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of four-dimensional (4D) flow magnetic resonance imaging (MRI) in quantifying aortic regurgitation: a comparison with two- dimensional (2D) MRI and echocardiography

Samia Mounir Zaki, Donia M. Sobh, Magda Ali Hany EL-Bakry, Hoda M. Sobh et al.
The Egyptian Journal of Radiology and Nuclear Medicine
Cardiac Valve Diseases and Treatments
article

Accuracy of four-dimensional (4D) flow magnetic resonance imaging (MRI) in quantifying aortic regurgitation: a comparison with two- dimensional (2D) MRI and echocardiography

Samia Mounir Zaki, Donia M. Sobh, Magda Ali Hany EL-Bakry, Hoda M. Sobh, Mohammed Sanad, Abdallah M Elshal, Sameh Elsayed
article en

Abstract

Abstract Background Aortic regurgitation (AR) is a common valvular disorder that may occur as an isolated lesion or alongside congenital heart disease (CHD). While transthoracic echocardiography (TTE) remains the primary imaging modality for diagnosing and grading AR, cardiovascular magnetic resonance (CMR) is increasingly used for its high accuracy in quantifying ventricular volumes and function. Traditional CMR relies on Two-Dimensional (2D) phase-contrast (PC) sequences with flow assessment limited to predefined planes. In hcontrast, Four-Dimensional (4D) flow CMR offers comprehensive volumetric coverage, enabling retrospective blood flow analysis at any location. This prospective study of 44 subjects (29 with AR and 15 healthy controls) aims to evaluate the diagnostic performance of 4D flow CMR in assessing aortic valve AR and to compare its performance with 2D-PC MRI and TTE. Results In AR patients, left ventricular parameters were significantly increased. Aortic regurgitant fraction (RF) values did not differ significantly between 2 and 4D flow MRI measured at levels of aortic valve and pulmonary artery. RF at aortic valve level was significantly lower than at supra-valvular levels. The highest concordance between 4D flow MRI and TTE for AR grading occurred at the pulmonary artery level. Conclusion 4D flow MRI provides reliable estimation of AR, with measurement of aortic RF at the pulmonary artery level showing the strongest agreement with echocardiographic grading, while measurement at aortic valve level tends to underestimate severity. These findings support pulmonary artery level assessment as the preferred site for accurate AR evaluation.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 57(1)
Mansoura University (EG)
Good health and well-being
Openalex Percentile: Top 51%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of four-dimensional (4D) flow magnetic resonance imaging (MRI) in quantifying aortic regurgitation: a comparison with two- dimensional (2D) MRI and echocardiography — Samia Mounir Zaki, Donia M. Sobh, et al. · The Egyptian Journal of Radiology and Nuclear Medicine (2026) | TGRS Research Map | TGRS