Comparison of commercial 1Tx32Rx vs 8Tx32Rx head coils for routine 7T neuroimaging

Human 7T MRI systems are manufactured by three vendors (Siemens, Philips, and GE) who all provide equivalent head coils from the same 3rd party manufacturer. Furthermore, many 7T MRI sites have two head coils available for neuroimaging: a 1Tx32Rx head coil for conventional single-channel transmit imaging and an 8Tx32Rx head coil for parallel-transmit (pTx) imaging. We compared the performance of these coils in six healthy volunteers. All scans were done on a 7T MRI (MAGNETOM Terra, Siemens, Germany). We tested seven sequences in wide use at our centre: B0 and B1+ mapping, anatomical T1-weighted MP2RAGE, R2*-mapping, single-voxel spectroscopy (MRS), echo-planar imaging time series, and diffusion tensor imaging (DTI). Sequences were run unmodified and without any pTx pulses. Data quality is comparable for both coils. The 8Tx32Rx coil had improved B1+ in inferior brain regions, enhanced spinal cord visibility in the cervical spine on anatomical MP2RAGE, higher SNR in MRS of the brainstem, and more defined fitted white matter tracts in the DTI images. All sequences showed acceptable data quality with the 8Tx32Rx coil. It is reasonable to substitute the 8Tx32Rx coil for the 1Tx32Rx coil for standard neuroimaging protocols. This will enable advanced parallel transmit sequences to be added to protocols with minimal disruption.

Authors

Publication Details

Journal
Apollo (University of Cambridge)
Published
2026-02-21
DOI
https://doi.org/10.17863/cam.127581
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of commercial 1Tx32Rx vs 8Tx32Rx head coils for routine 7T neuroimaging

Krzysztof Kłodowski, Belinda Ding, Catarina R Rua, Carina Graf et al.
Apollo (University of Cambridge)
Advanced MRI Techniques and Applications
article

Comparison of commercial 1Tx32Rx vs 8Tx32Rx head coils for routine 7T neuroimaging

Krzysztof Kłodowski, Belinda Ding, Catarina R Rua, Carina Graf, Christopher Rodgers
article en

Abstract

Human 7T MRI systems are manufactured by three vendors (Siemens, Philips, and GE) who all provide equivalent head coils from the same 3rd party manufacturer. Furthermore, many 7T MRI sites have two head coils available for neuroimaging: a 1Tx32Rx head coil for conventional single-channel transmit imaging and an 8Tx32Rx head coil for parallel-transmit (pTx) imaging. We compared the performance of these coils in six healthy volunteers. All scans were done on a 7T MRI (MAGNETOM Terra, Siemens, Germany). We tested seven sequences in wide use at our centre: B0 and B1+ mapping, anatomical T1-weighted MP2RAGE, R2*-mapping, single-voxel spectroscopy (MRS), echo-planar imaging time series, and diffusion tensor imaging (DTI). Sequences were run unmodified and without any pTx pulses. Data quality is comparable for both coils. The 8Tx32Rx coil had improved B1+ in inferior brain regions, enhanced spinal cord visibility in the cervical spine on anatomical MP2RAGE, higher SNR in MRS of the brainstem, and more defined fitted white matter tracts in the DTI images. All sequences showed acceptable data quality with the 8Tx32Rx coil. It is reasonable to substitute the 8Tx32Rx coil for the 1Tx32Rx coil for standard neuroimaging protocols. This will enable advanced parallel transmit sequences to be added to protocols with minimal disruption.

Apollo (University of Cambridge)
Openalex Percentile: Top 48%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of commercial 1Tx32Rx vs 8Tx32Rx head coils for routine 7T neuroimaging — Krzysztof Kłodowski, Belinda Ding, et al. · Apollo (University of Cambridge) (2026) | TGRS Research Map | TGRS