Standardisation in robotic surgery for inflammatory bowel disease: a systematic review

Robotic-assisted surgery offers technical advantages over laparoscopy, including improved dexterity and visualisation. However, its role in inflammatory bowel disease (IBD) remains poorly defined, with existing studies limited by variability and lack of standardisation. This systematic review aimed to evaluate the reproducibility, operative detail, outcome reporting, and procedural consistency in the current literature on robotic-assisted surgery for IBD. A systematic review was conducted following PRISMA 2020 guidelines and registered on PROSPERO (CRD42024514488). Comprehensive searches of five databases and grey literature from January 2015 to April 2024 were performed. Studies involving robotic surgery in adult IBD patients were included. Methodological quality was assessed using the Newcastle–Ottawa Scale. Sixteen studies involving 614 patients met inclusion criteria. Most were retrospective (81.3%) and single-arm (62.5%), with robotic ileocolic resection being the most common procedure (50%). Significant heterogeneity existed in port placement, docking, and intraoperative techniques. Technical reporting, particularly on robotic setup, was inconsistent. Definitions of postoperative outcomes, including complications and conversion rates, varied across studies. Enhanced Recovery After Surgery protocols were used in 18.8% of studies, with minimal reporting of patient-reported outcomes. While risk of bias was generally low, limited follow-up and absence of comparator arms reduced the strength of conclusions. Current evidence on robotic surgery in IBD is methodologically variable and poorly standardised, particularly regarding technical setup and outcome definitions. Future research should focus on prospective, multicentre studies with detailed intraoperative data, standardised outcomes, and long-term follow-up.

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2026-02-21
DOI
https://doi.org/10.1007/s11701-026-03194-y
Primary Topic
Inflammatory Bowel Disease
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Standardisation in robotic surgery for inflammatory bowel disease: a systematic review

Shobhit Arya, Aliki Rompou, Ayesha Unadkat
Journal of Robotic Surgery
Inflammatory Bowel Disease
article

Standardisation in robotic surgery for inflammatory bowel disease: a systematic review

Shobhit Arya, Aliki Rompou, Ayesha Unadkat
article en

Abstract

Robotic-assisted surgery offers technical advantages over laparoscopy, including improved dexterity and visualisation. However, its role in inflammatory bowel disease (IBD) remains poorly defined, with existing studies limited by variability and lack of standardisation. This systematic review aimed to evaluate the reproducibility, operative detail, outcome reporting, and procedural consistency in the current literature on robotic-assisted surgery for IBD. A systematic review was conducted following PRISMA 2020 guidelines and registered on PROSPERO (CRD42024514488). Comprehensive searches of five databases and grey literature from January 2015 to April 2024 were performed. Studies involving robotic surgery in adult IBD patients were included. Methodological quality was assessed using the Newcastle–Ottawa Scale. Sixteen studies involving 614 patients met inclusion criteria. Most were retrospective (81.3%) and single-arm (62.5%), with robotic ileocolic resection being the most common procedure (50%). Significant heterogeneity existed in port placement, docking, and intraoperative techniques. Technical reporting, particularly on robotic setup, was inconsistent. Definitions of postoperative outcomes, including complications and conversion rates, varied across studies. Enhanced Recovery After Surgery protocols were used in 18.8% of studies, with minimal reporting of patient-reported outcomes. While risk of bias was generally low, limited follow-up and absence of comparator arms reduced the strength of conclusions. Current evidence on robotic surgery in IBD is methodologically variable and poorly standardised, particularly regarding technical setup and outcome definitions. Future research should focus on prospective, multicentre studies with detailed intraoperative data, standardised outcomes, and long-term follow-up.

Journal of Robotic SurgeryVol. 20(1)
Chelsea and Westminster Hospital (GB), Imperial College London (GB)
Openalex Percentile: Top 45%
Inflammatory Bowel Disease
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Standardisation in robotic surgery for inflammatory bowel disease: a systematic review — Shobhit Arya, Aliki Rompou, et al. · Journal of Robotic Surgery (2026) | TGRS Research Map | TGRS