Safe focused ultrasound-mediated blood-brain barrier opening is driven primarily by transient reorganization of tight junctions

Focused ultrasound (FUS) with microbubbles opens the blood-brain barrier (BBB) for targeted drug delivery into the brain. How brain endothelial cells (BECs) respond to low acoustic pressures known to open the BBB transiently, or high pressures that cause brain damage, is incompletely characterized. Here, we apply FUS at low (450 kPa) and high (750 kPa) pressures in mice where BBB tight junctions are labeled with eGFP to characterize their abnormalities. Arteriole and capillary BECs respond to low pressure by a transient BBB tight junction reorganization and opening. In contrast, high pressure induces tight junction obliteration and persistent BBB opening in BECs even after 72 hours, associated with microglial activation. Transcriptomic analyses of BECs show that high pressure upregulates genes related to the stress response and cell junction disassembly, whereas low pressure upregulates intracellular repair genes. Thus, transient reorganization and repair of tight junctions mediate safe BBB opening for therapeutic delivery.

Authors

Institutions

Publication Details

Journal
Communications Engineering
Published
2026-02-21
DOI
https://doi.org/10.1038/s44172-026-00597-5
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safe focused ultrasound-mediated blood-brain barrier opening is driven primarily by transient reorganization of tight junctions

Daniella A. Jimenez, Yusuke Nimi, Claire Choi, Robin Ji et al.
Communications Engineering
Ultrasound and Hyperthermia Applications
article

Safe focused ultrasound-mediated blood-brain barrier opening is driven primarily by transient reorganization of tight junctions

Daniella A. Jimenez, Yusuke Nimi, Claire Choi, Robin Ji, Dritan Agalliu, Rebecca L. Noel, Sanjid Shahriar, Tara Kugelman, Elisa E. Konofagou, Moshe J. Willner
article en

Abstract

Focused ultrasound (FUS) with microbubbles opens the blood-brain barrier (BBB) for targeted drug delivery into the brain. How brain endothelial cells (BECs) respond to low acoustic pressures known to open the BBB transiently, or high pressures that cause brain damage, is incompletely characterized. Here, we apply FUS at low (450 kPa) and high (750 kPa) pressures in mice where BBB tight junctions are labeled with eGFP to characterize their abnormalities. Arteriole and capillary BECs respond to low pressure by a transient BBB tight junction reorganization and opening. In contrast, high pressure induces tight junction obliteration and persistent BBB opening in BECs even after 72 hours, associated with microglial activation. Transcriptomic analyses of BECs show that high pressure upregulates genes related to the stress response and cell junction disassembly, whereas low pressure upregulates intracellular repair genes. Thus, transient reorganization and repair of tight junctions mediate safe BBB opening for therapeutic delivery.

Communications Engineering
Columbia University Irving Medical Center (US), Columbia University (US)
National Institutes of Health, Irving Medical Center, Columbia University
Good health and well-being
Openalex Percentile: Top 49%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.