Two-layer dynamic blood phantom for assessing NIRS device accuracy

Near-infrared spectroscopy (NIRS) is a widely used non-invasive method for measuring oxygenation and hemodynamics. NIRS devices are validated using phantoms that accurately replicate the optical properties of human tissue. The aim was to develop a multi-layer blood-lipid phantom specifically to mimic the layered anatomical structure of the human head. The phantom consists of two adjustable liquid layers, which model the optical properties and dynamic characteristics of brain and superficial tissues, together with two fixed solid layers. We demonstrate our phantom capabilities by testing the INVOS 7100 and Masimo O3 NIRS devices. The phantom enabled the Masimo instrument to show that it is less influenced by superficial changes (RMSE relative to superficial layer ∼50%) than the INVOS instrument (∼35%), highlighting better depth sensitivity. This shows the phantom's value as a tool for guiding device development and evaluation.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-09-01
DOI
https://doi.org/10.5167/uzh-291890
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-layer dynamic blood phantom for assessing NIRS device accuracy

Letizia Lanini, Alexander Kalyanov, Emanuele Russomanno, H Zohdi et al.
Universität Zürich, ZORA
Optical Imaging and Spectroscopy Techniques
article

Two-layer dynamic blood phantom for assessing NIRS device accuracy

Letizia Lanini, Alexander Kalyanov, Emanuele Russomanno, H Zohdi, Martin Wolf, M Ackermann, D Yacheur, Jingjing Jiang, X. Yang
article en

Abstract

Near-infrared spectroscopy (NIRS) is a widely used non-invasive method for measuring oxygenation and hemodynamics. NIRS devices are validated using phantoms that accurately replicate the optical properties of human tissue. The aim was to develop a multi-layer blood-lipid phantom specifically to mimic the layered anatomical structure of the human head. The phantom consists of two adjustable liquid layers, which model the optical properties and dynamic characteristics of brain and superficial tissues, together with two fixed solid layers. We demonstrate our phantom capabilities by testing the INVOS 7100 and Masimo O3 NIRS devices. The phantom enabled the Masimo instrument to show that it is less influenced by superficial changes (RMSE relative to superficial layer ∼50%) than the INVOS instrument (∼35%), highlighting better depth sensitivity. This shows the phantom's value as a tool for guiding device development and evaluation.

Universität Zürich, ZORA
Openalex Percentile: Top 26%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Two-layer dynamic blood phantom for assessing NIRS device accuracy — Letizia Lanini, Alexander Kalyanov, et al. · Universität Zürich, ZORA (2025) | TGRS Research Map | TGRS