Implant-agnostic, handheld wireless robotics: multicenter efficiency and learning curve for total knee arthroplasty

As robotic total knee arthroplasty (TKA) adoption grows, the learning curve for new users remains a concern for both physicians and staff. Previous studies have reported on clinical outcomes for TKA with a novel implant-agnostic, handheld, wireless robotic TKA system (rTKA). This study investigates the rTKA adoption learning curve relevant to multiple clinical stakeholders. This multicenter, multi-surgeon observational study includes up to the first 25 rTKA procedures by 7 surgeons. Observers noted timing and workflow at 8/25 rTKA cases and 2 standard-of-care benchmark TKAs (prior manual or robotic use by user), and analyzed logs for all rTKA cases. Learning curves were assessed via benchmark TKA time neutrality, statistical comparison between early and later cases, and cumulative sum (CUSUM) analysis. Surgeon and staff surveys followed each observed rTKA case. Each analysis type demonstrated a different learning curve duration: surgeons averaged approximately 10 cases to time neutrality, with 2 not reaching time neutrality within the observed case series. Cases 3 and onward were significantly faster than cases 1–2 (p = 0.0454), indicating early operative time improvement after initial system exposure. Average observed skin-to-skin time was 68 min. Surgeons and staff rated the system easy to use and were familiar with the system after 4 cases. Use of the handheld surgical robot for rTKA demonstrated a short learning curve and high reported ease of adoption by surgeons and staff. This study demonstrates the rTKA system exhibits a short learning curve and high reported ease of adoption, and may compare favorably with previously reported learning curves for other robotic TKA systems. Level of evidence: IV.

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2026-02-21
DOI
https://doi.org/10.1007/s11701-026-03242-7
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implant-agnostic, handheld wireless robotics: multicenter efficiency and learning curve for total knee arthroplasty

James L Womack, Trevor Cotter, Alexander P. Sah, Yair D. Kissin et al.
Journal of Robotic Surgery
Total Knee Arthroplasty Outcomes
article

Implant-agnostic, handheld wireless robotics: multicenter efficiency and learning curve for total knee arthroplasty

James L Womack, Trevor Cotter, Alexander P. Sah, Yair D. Kissin, Eytan M. Debbi
article en

Abstract

As robotic total knee arthroplasty (TKA) adoption grows, the learning curve for new users remains a concern for both physicians and staff. Previous studies have reported on clinical outcomes for TKA with a novel implant-agnostic, handheld, wireless robotic TKA system (rTKA). This study investigates the rTKA adoption learning curve relevant to multiple clinical stakeholders. This multicenter, multi-surgeon observational study includes up to the first 25 rTKA procedures by 7 surgeons. Observers noted timing and workflow at 8/25 rTKA cases and 2 standard-of-care benchmark TKAs (prior manual or robotic use by user), and analyzed logs for all rTKA cases. Learning curves were assessed via benchmark TKA time neutrality, statistical comparison between early and later cases, and cumulative sum (CUSUM) analysis. Surgeon and staff surveys followed each observed rTKA case. Each analysis type demonstrated a different learning curve duration: surgeons averaged approximately 10 cases to time neutrality, with 2 not reaching time neutrality within the observed case series. Cases 3 and onward were significantly faster than cases 1–2 (p = 0.0454), indicating early operative time improvement after initial system exposure. Average observed skin-to-skin time was 68 min. Surgeons and staff rated the system easy to use and were familiar with the system after 4 cases. Use of the handheld surgical robot for rTKA demonstrated a short learning curve and high reported ease of adoption by surgeons and staff. This study demonstrates the rTKA system exhibits a short learning curve and high reported ease of adoption, and may compare favorably with previously reported learning curves for other robotic TKA systems. Level of evidence: IV.

Journal of Robotic SurgeryVol. 20(1)
Hospital for Special Surgery (US), Hackensack University Medical Center (US), Think Surgical (United States) (US), Memorial Healthcare System (US), Washington Hospital Healthcare System (US)
Openalex Percentile: Top 48%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.