Long-term management of leadless pacemakers

Leadless pacemakers (LPs) are increasingly being used to treat bradyarrhythmias, and end of service (EOS) management decisions are becoming increasingly important given finite battery lifespans. Two strategies have been adopted for device EOS: LP abandonment and LP removal. Certain scenarios including high degree of LP encapsulation and 'last expected' pacing devices favour LP abandonment, while other LP complications may necessitate device removal. When abandoning LP, clinicians must understand design, performance, and safety considerations for devices left in place. When removing LP, specialized tools and techniques have been developed, each varying by device manufacturer and model. Case reports and series on LP removal have elucidated how to overcome challenges that may arise during removal. Despite best practice techniques, complications can arise before and after removal. Current studies on LP EOS management are limited, and further studies are needed to help understand predictors of successful device removal and long-term sequelae of both strategies. The aim of this state-of-the-art review is to help clinicians understand current strategies and considerations for both LP abandonment and removal.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-03-01
DOI
https://doi.org/10.5167/uzh-291730
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-term management of leadless pacemakers

Andrew Andreae, Jonathan P Piccini, Alexander Breitenstein
Universität Zürich, ZORA
Cardiac pacing and defibrillation studies
article

Long-term management of leadless pacemakers

Andrew Andreae, Jonathan P Piccini, Alexander Breitenstein
article en

Abstract

Leadless pacemakers (LPs) are increasingly being used to treat bradyarrhythmias, and end of service (EOS) management decisions are becoming increasingly important given finite battery lifespans. Two strategies have been adopted for device EOS: LP abandonment and LP removal. Certain scenarios including high degree of LP encapsulation and 'last expected' pacing devices favour LP abandonment, while other LP complications may necessitate device removal. When abandoning LP, clinicians must understand design, performance, and safety considerations for devices left in place. When removing LP, specialized tools and techniques have been developed, each varying by device manufacturer and model. Case reports and series on LP removal have elucidated how to overcome challenges that may arise during removal. Despite best practice techniques, complications can arise before and after removal. Current studies on LP EOS management are limited, and further studies are needed to help understand predictors of successful device removal and long-term sequelae of both strategies. The aim of this state-of-the-art review is to help clinicians understand current strategies and considerations for both LP abandonment and removal.

Universität Zürich, ZORA
Openalex Percentile: Top 25%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.