Abstract PS4-04-07: Improved Diagnostic Accuracy for Breast Implant Rupture Through Strain Elastography - Results of a User-Based Evaluation Using Standardized Image Sets

Abstract Background: Ultrasound is a widely used tool for evaluating breast implant integrity, but its diagnostic accuracy remains limited by operator dependency. This study investigated whether the addition of strain elastography can improve diagnostic sensitivity and specificity in detecting implant rupture. Methods: Based on a standardized animal model, 15 silicone breast implants (intact and ruptured) were scanned using both B-mode ultrasound and strain elastography. From these scans, 30 paired images were selected for an online evaluation. In total, 99 participants reviewed the image sets and were asked to determine the presence or absence of implant rupture — first using B-mode images alone, and then with the corresponding elastography images. Results: With B-mode alone, participants achieved a diagnostic sensitivity of 81.4% and specificity of 71.0%. When strain elastography was added, sensitivity rose to 90.9%, and specificity increased to 87.6%. Conclusion: The integration of strain elastography significantly enhances diagnostic performance in assessing breast implant rupture. In particular, it reduces false-positive rates while increasing detection of true ruptures. Using standardized image data from an animal model enables reproducible evaluation and may serve as a basis for future training and quality assurance in breast imaging. Citation Format: H. Fritsch, L. Borchert, L. Paul, K. Hide-Moser, C. Vogel-Minea, C. Eichler. Improved Diagnostic Accuracy for Breast Implant Rupture Through Strain Elastography - Results of a User-Based Evaluation Using Standardized Image Sets [abstract]. In: Proceedings of the San Antonio Breast Cancer Symposium 2025; 2025 Dec 9-12; San Antonio, TX. Philadelphia (PA): AACR; Clin Cancer Res 2026;32(4 Suppl):Abstract nr PS4-04-07.

Authors

Institutions

Publication Details

Journal
Clinical Cancer Research
Published
2026-02-17
DOI
https://doi.org/10.1158/1557-3265.sabcs25-ps4-04-07
Primary Topic
Breast Implant and Reconstruction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract PS4-04-07: Improved Diagnostic Accuracy for Breast Implant Rupture Through Strain Elastography - Results of a User-Based Evaluation Using Standardized Image Sets

Luther G. Paul, Christian Eichler, Katherina Hide-Moser, H. Fritsch et al.
Clinical Cancer Research
Breast Implant and Reconstruction
article

Abstract PS4-04-07: Improved Diagnostic Accuracy for Breast Implant Rupture Through Strain Elastography - Results of a User-Based Evaluation Using Standardized Image Sets

Luther G. Paul, Christian Eichler, Katherina Hide-Moser, H. Fritsch, C. Vogel-Minea, L. Borchert
article en

Abstract

Abstract Background: Ultrasound is a widely used tool for evaluating breast implant integrity, but its diagnostic accuracy remains limited by operator dependency. This study investigated whether the addition of strain elastography can improve diagnostic sensitivity and specificity in detecting implant rupture. Methods: Based on a standardized animal model, 15 silicone breast implants (intact and ruptured) were scanned using both B-mode ultrasound and strain elastography. From these scans, 30 paired images were selected for an online evaluation. In total, 99 participants reviewed the image sets and were asked to determine the presence or absence of implant rupture — first using B-mode images alone, and then with the corresponding elastography images. Results: With B-mode alone, participants achieved a diagnostic sensitivity of 81.4% and specificity of 71.0%. When strain elastography was added, sensitivity rose to 90.9%, and specificity increased to 87.6%. Conclusion: The integration of strain elastography significantly enhances diagnostic performance in assessing breast implant rupture. In particular, it reduces false-positive rates while increasing detection of true ruptures. Using standardized image data from an animal model enables reproducible evaluation and may serve as a basis for future training and quality assurance in breast imaging. Citation Format: H. Fritsch, L. Borchert, L. Paul, K. Hide-Moser, C. Vogel-Minea, C. Eichler. Improved Diagnostic Accuracy for Breast Implant Rupture Through Strain Elastography - Results of a User-Based Evaluation Using Standardized Image Sets [abstract]. In: Proceedings of the San Antonio Breast Cancer Symposium 2025; 2025 Dec 9-12; San Antonio, TX. Philadelphia (PA): AACR; Clin Cancer Res 2026;32(4 Suppl):Abstract nr PS4-04-07.

Clinical Cancer ResearchVol. 32(4_Supplement)
Krankenhaus vom Roten Kreuz (DE), St. Franziskus Hospital (DE), University Hospital Cologne (DE)
Openalex Percentile: Top 49%
Breast Implant and Reconstruction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.