Impact of unfavorable aortic anatomy on transcatheter aortic valve replacement outcomes.

Background Despite device improvements for transcatheter aortic valve replacement (TAVR) and increased operator expertise, unfavorable aortic root anatomy might subtend worse procedural and clinical outcomes. The aim of the study is to assess procedural and clinical outcomes of transfemoral TAVR in patients with and without unfavorable aortic root anatomy and receiving Evolut PRO/PRO+ or SAPIEN 3 Ultra devices in contemporary clinical practice.Methods Patients enrolled in the multicenter OPERA-TAVI registry were considered. Patients were compared using propensity score matching according to the presence or absence of unfavorable anatomical characteristics of the aortic root [bicuspid aortic valve (BAV), moderate-to-severe left ventricular outflow tract calcifications, horizontal aorta]. Primary endpoints were Valve Academic Research Consortium (VARC)-3 device success and early safety. The secondary endpoint was a composite of 1-year all-cause death, disabling stroke and heart failure rehospitalization.Results Among a total of 1815 patients, 629 patients (34.7%) had at least one unfavorable characteristic. After adjustment, 624 matched pairs of patients were compared.VARC-3 device success (85.3% vs. 92.0%, P < 0.001) and early safety (72.9% vs. 79.6%, P = 0.006) were lower in patients with unfavorable characteristics. The secondary composite endpoint was higher in patients with unfavorable anatomical characteristics (Kaplan-Meier estimates 15.3 vs. 12.0%; Plogrank = 0.019). Among patients with unfavorable anatomical characteristics, BAV alone was associated with early safety [odds ratio 2.15, 95% confidence interval 1.04-4.70, P = 0.05].Conclusions Patients undergoing transfemoral TAVR had lower rates of device success and early safety in the presence of unfavorable anatomical characteristics, along with worse 1-year clinical outcomes. However, BAV was associated with higher early safety in this context.

Authors

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-02-01
DOI
https://doi.org/10.48620/94772
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of unfavorable aortic anatomy on transcatheter aortic valve replacement outcomes.

Matías Mon-Noboa, Daijiro Tomii, Sofia Sammartino, Giulia Laterra et al.
Open Access CRIS of the University of Bern
Cardiac Valve Diseases and Treatments
article

Impact of unfavorable aortic anatomy on transcatheter aortic valve replacement outcomes.

Matías Mon-Noboa, Daijiro Tomii, Sofia Sammartino, Giulia Laterra, Federica Agnello, S. Motta, Stefano Andreaggi, Claudia Reddavid, Mariachiara Calì, Roberto Valvo, Breda Hennessey, Luca Branca, Mariama Akodad, Lars Søndergaard, Flavio Ribichini, Pietro Laforgia, Simone Fezzi, Enrico Poletti, Luis Nombela Franco, Marianna Adamo, Ole De Backer, Alessandro Comis, Mohamed Abdel-Wahab, Mattia Lunardi, Azeem Latib, Angelo Quagliana, Francesco Bedogni, Nicholas Montarello, Federico De Marco, Caterina Gandolfo, Ignacio Amat Santos, John G Webb, Holger Thiele, Francesco Saia, Andrea Mainardi, Enrico Criscione, Thomas Pilgrim, Corrado Tamburino, Orazio Strazzieri, Andrea Scotti, Tullio Palmerini, Marco Barbanti, Valentina Frittitta, Philippe Garot, Luigi La Rosa, Darren Mylotte, Stefano Cannata, Elena Dipietro, David Meier, Carmelo Sgroi, Giuliano Costa
article en

Abstract

Background Despite device improvements for transcatheter aortic valve replacement (TAVR) and increased operator expertise, unfavorable aortic root anatomy might subtend worse procedural and clinical outcomes. The aim of the study is to assess procedural and clinical outcomes of transfemoral TAVR in patients with and without unfavorable aortic root anatomy and receiving Evolut PRO/PRO+ or SAPIEN 3 Ultra devices in contemporary clinical practice.Methods Patients enrolled in the multicenter OPERA-TAVI registry were considered. Patients were compared using propensity score matching according to the presence or absence of unfavorable anatomical characteristics of the aortic root [bicuspid aortic valve (BAV), moderate-to-severe left ventricular outflow tract calcifications, horizontal aorta]. Primary endpoints were Valve Academic Research Consortium (VARC)-3 device success and early safety. The secondary endpoint was a composite of 1-year all-cause death, disabling stroke and heart failure rehospitalization.Results Among a total of 1815 patients, 629 patients (34.7%) had at least one unfavorable characteristic. After adjustment, 624 matched pairs of patients were compared.VARC-3 device success (85.3% vs. 92.0%, P < 0.001) and early safety (72.9% vs. 79.6%, P = 0.006) were lower in patients with unfavorable characteristics. The secondary composite endpoint was higher in patients with unfavorable anatomical characteristics (Kaplan-Meier estimates 15.3 vs. 12.0%; Plogrank = 0.019). Among patients with unfavorable anatomical characteristics, BAV alone was associated with early safety [odds ratio 2.15, 95% confidence interval 1.04-4.70, P = 0.05].Conclusions Patients undergoing transfemoral TAVR had lower rates of device success and early safety in the presence of unfavorable anatomical characteristics, along with worse 1-year clinical outcomes. However, BAV was associated with higher early safety in this context.

Open Access CRIS of the University of Bern
Good health and well-being
Openalex Percentile: Top 53%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.