Waveform-aware deep learning for quantitative agglutination on a low-cost lab-in-tubing microfluidic platform

To enable quantitative agglutination readout using an ultra-low-cost (parts cost < $40) lab-in-tubing optical platform. Droplet waveforms were recorded with dual infrared line-break sensors from biotinylated BSA mixed with streptavidin-coated beads at nine levels (0, 0.0128–1000 μg mL-1; N = 223 droplets, N = 211 after QC). We apply waveform-aware preprocessing (i.e., preprocessing operations defined on the full time-series waveform that preserve concentration-dependent morphology rather than reducing the signal to a single scalar) (length normalization, Hampel spike suppression, offset-drift compensation, quality-control filtering, and blank (0 μg mL-1) reference subtraction) and train a one-dimensional convolutional neural network (1D-CNN) to regress log10(concentration). Results: On a stratified 80/20 validation split, the model achieved MAE = 30.49 μg mL-1 with sub-μg absolute errors at trace-to-mid concentrations and larger but scale-appropriate deviations near the apex (~8 μg mL-1) and in the prozone. Leave-one-concentration-out (LOCO) experiments show that errors increase primarily at omitted calibration anchors, motivating a minimal three-anchor scheme (low, apex, high/prozone) for stable interpolation. Conclusion: Coupling inexpensive optics with waveform-level modeling supports quantitative agglutination estimation across nearly five orders of magnitude (0.0128–1000 μg mL-1). Multi-day, multi-device, and matrix-effect validation remain future work. LOCO is a special case of leave-group-out cross-validation [26], and we use it here to emulate missing calibration anchors [27]. • Waveform-aware preprocessing isolates agglutination morphology from low-cost optical signals. • 1D-CNN regression estimates concentration across 0.0128–1000 μg mL-1 (nearly 5 orders). • LOCO analysis motivates a three-anchor calibration strategy (low, apex, high/prozone).

Authors

Institutions

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2026-02-01
DOI
https://doi.org/10.1016/j.sbsr.2026.100983
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Waveform-aware deep learning for quantitative agglutination on a low-cost lab-in-tubing microfluidic platform

Abbas S. Milani, Ian G. Foulds, Abdul Basit Zia, Justin Farrell et al.
Sensing and Bio-Sensing Research
Innovative Microfluidic and Catalytic Techniques Innovation
article

Waveform-aware deep learning for quantitative agglutination on a low-cost lab-in-tubing microfluidic platform

Abbas S. Milani, Ian G. Foulds, Abdul Basit Zia, Justin Farrell, Rohith Jayaraman Krishnamurthy
article en

Abstract

To enable quantitative agglutination readout using an ultra-low-cost (parts cost < $40) lab-in-tubing optical platform. Droplet waveforms were recorded with dual infrared line-break sensors from biotinylated BSA mixed with streptavidin-coated beads at nine levels (0, 0.0128–1000 μg mL-1; N = 223 droplets, N = 211 after QC). We apply waveform-aware preprocessing (i.e., preprocessing operations defined on the full time-series waveform that preserve concentration-dependent morphology rather than reducing the signal to a single scalar) (length normalization, Hampel spike suppression, offset-drift compensation, quality-control filtering, and blank (0 μg mL-1) reference subtraction) and train a one-dimensional convolutional neural network (1D-CNN) to regress log10(concentration). Results: On a stratified 80/20 validation split, the model achieved MAE = 30.49 μg mL-1 with sub-μg absolute errors at trace-to-mid concentrations and larger but scale-appropriate deviations near the apex (~8 μg mL-1) and in the prozone. Leave-one-concentration-out (LOCO) experiments show that errors increase primarily at omitted calibration anchors, motivating a minimal three-anchor scheme (low, apex, high/prozone) for stable interpolation. Conclusion: Coupling inexpensive optics with waveform-level modeling supports quantitative agglutination estimation across nearly five orders of magnitude (0.0128–1000 μg mL-1). Multi-day, multi-device, and matrix-effect validation remain future work. LOCO is a special case of leave-group-out cross-validation [26], and we use it here to emulate missing calibration anchors [27]. • Waveform-aware preprocessing isolates agglutination morphology from low-cost optical signals. • 1D-CNN regression estimates concentration across 0.0128–1000 μg mL-1 (nearly 5 orders). • LOCO analysis motivates a three-anchor calibration strategy (low, apex, high/prozone).

Sensing and Bio-Sensing ResearchVol. 51
University of British Columbia (CA)
Openalex Percentile: Top 51%
Innovative Microfluidic and Catalytic Techniques Innovation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.