Enhancing the prediction of heating and cooling loads in residential buildings using explainable XGBoost: a comparative analysis of SHAP and LIME techniques

Accurate prediction of building thermal demands is essential for evaluating energy efficiency and optimizing performance within energy management systems. This need has become increasingly critical due to growing environmental concerns surrounding energy consumption and its ecological impact. Reliable estimation of energy demands supports informed decision-making in resource management and carbon footprint reduction, promoting sustainable and technologically advanced construction practices. This study investigates the predictive accuracy of several ensemble boosting algorithms in estimating thermal energy demands (heating and cooling loads) using different architectural parameters. The performance evaluation using RMSE metrics demonstrated XGBoost’s dominance across both thermal prediction tasks. For heating load estimation, this algorithm yielded the lowest error rate of 0.309 kW, surpassing CatBoost’s 0.318 kW and LightGBM’s 0.351 kW results. In cooling load forecasting, XGBoost maintained its leading position with 0.731 kW RMSE, outperforming LightGBM (0.907 kW) and CatBoost (0.917 kW), which occupied the subsequent ranking positions. Testing phase findings across heating and cooling load predictions confirmed that the XGBoost ensemble methodology successfully improved estimation accuracy when applied to thermal demand modeling with associated parameters. Moreover, SHAP analysis revealed that glazing area distribution and orientation had minimal impact on heating load predictions, while overall height and relative compactness were the most influential. Similarly, orientation and glazing area distribution parameters contribute the least to the prediction of cooling load, whereas overall height and relative compactness parameters have the most significant influence. These findings confirm the effectiveness of XGBoost in enhancing prediction accuracy for residential thermal demand modeling.

Authors

Institutions

Publication Details

Journal
Artificial Intelligence Review
Published
2026-02-19
DOI
https://doi.org/10.1007/s10462-026-11521-w
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the prediction of heating and cooling loads in residential buildings using explainable XGBoost: a comparative analysis of SHAP and LIME techniques

S. H. Kim, Meysam Alizamir, Salim Heddam, Aliakbar Gholampour et al.
Artificial Intelligence Review
Building Energy and Comfort Optimization
article

Enhancing the prediction of heating and cooling loads in residential buildings using explainable XGBoost: a comparative analysis of SHAP and LIME techniques

S. H. Kim, Meysam Alizamir, Salim Heddam, Aliakbar Gholampour, Hyounseok Moon
article en

Abstract

Accurate prediction of building thermal demands is essential for evaluating energy efficiency and optimizing performance within energy management systems. This need has become increasingly critical due to growing environmental concerns surrounding energy consumption and its ecological impact. Reliable estimation of energy demands supports informed decision-making in resource management and carbon footprint reduction, promoting sustainable and technologically advanced construction practices. This study investigates the predictive accuracy of several ensemble boosting algorithms in estimating thermal energy demands (heating and cooling loads) using different architectural parameters. The performance evaluation using RMSE metrics demonstrated XGBoost’s dominance across both thermal prediction tasks. For heating load estimation, this algorithm yielded the lowest error rate of 0.309 kW, surpassing CatBoost’s 0.318 kW and LightGBM’s 0.351 kW results. In cooling load forecasting, XGBoost maintained its leading position with 0.731 kW RMSE, outperforming LightGBM (0.907 kW) and CatBoost (0.917 kW), which occupied the subsequent ranking positions. Testing phase findings across heating and cooling load predictions confirmed that the XGBoost ensemble methodology successfully improved estimation accuracy when applied to thermal demand modeling with associated parameters. Moreover, SHAP analysis revealed that glazing area distribution and orientation had minimal impact on heating load predictions, while overall height and relative compactness were the most influential. Similarly, orientation and glazing area distribution parameters contribute the least to the prediction of cooling load, whereas overall height and relative compactness parameters have the most significant influence. These findings confirm the effectiveness of XGBoost in enhancing prediction accuracy for residential thermal demand modeling.

Artificial Intelligence ReviewVol. 59(4)
Flinders University (AU), Duy Tan University (VN), Dongyang University (KR), Korea Institute of Civil Engineering and Building Technology (KR), University of Skikda (DZ)
Openalex Percentile: Top 50%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.