A novel AI-enhanced microwave sensor employing defected ground structure for non-invasive glucose monitoring

Diabetes is a chronic disease that affects millions of people worldwide and significantly reduces quality of life. One of the most critical aspects of managing this condition is the accurate, continuous, and reliable monitoring of blood glucose levels. Fluctuations in glucose concentration can lead to both short-term complications and long-term irreversible organ damage. Currently, traditional glucose monitoring methods rely mainly on blood samples obtained through finger-pricking. While these methods are accurate, their invasive nature reduces user comfort, causes pain, poses a risk of infection, and negatively affects patient adherence in the long run. In response to these limitations, non-invasive glucose monitoring technologies, particularly those based on microwave and radio frequency (RF) sensor systems, have gained increasing attention. However, most reported systems still face challenges in achieving high sensitivity and stability under realistic physiological conditions. In this study, we introduce a novel hexagonal microstrip patch antenna with a chaotic Defected Ground Structure (DGS) based on a Duffing chaotic attractor, specifically designed for non-invasive blood glucose sensing. Unlike conventional DGS-based sensors, our chaotic DGS approach enhances tissue penetration and significantly improves sensitivity to subtle dielectric variations caused by glucose concentration changes. The sensor, optimized for finger placement, operates in the 4–5 GHz range to ensure effective tissue coupling. Experimental validation using multi-layer tissue-mimicking phantoms demonstrated the sensor’s ability to differentiate clinically relevant glucose levels (50–200 mg/dL), achieving a high sensitivity of 0.950 MHz/(mg/dL).

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-19
DOI
https://doi.org/10.1038/s41598-026-40171-9
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel AI-enhanced microwave sensor employing defected ground structure for non-invasive glucose monitoring

Fatih Özkan Alkurt, Yakup HAMEŞ, Tatjana Gric, Fikret Alpay Tekşen et al.
Scientific Reports
Microwave and Dielectric Measurement Techniques
article

A novel AI-enhanced microwave sensor employing defected ground structure for non-invasive glucose monitoring

Fatih Özkan Alkurt, Yakup HAMEŞ, Tatjana Gric, Fikret Alpay Tekşen, Berker Çolak, Seda Aygül, Edik Rafaliov
article en

Abstract

Diabetes is a chronic disease that affects millions of people worldwide and significantly reduces quality of life. One of the most critical aspects of managing this condition is the accurate, continuous, and reliable monitoring of blood glucose levels. Fluctuations in glucose concentration can lead to both short-term complications and long-term irreversible organ damage. Currently, traditional glucose monitoring methods rely mainly on blood samples obtained through finger-pricking. While these methods are accurate, their invasive nature reduces user comfort, causes pain, poses a risk of infection, and negatively affects patient adherence in the long run. In response to these limitations, non-invasive glucose monitoring technologies, particularly those based on microwave and radio frequency (RF) sensor systems, have gained increasing attention. However, most reported systems still face challenges in achieving high sensitivity and stability under realistic physiological conditions. In this study, we introduce a novel hexagonal microstrip patch antenna with a chaotic Defected Ground Structure (DGS) based on a Duffing chaotic attractor, specifically designed for non-invasive blood glucose sensing. Unlike conventional DGS-based sensors, our chaotic DGS approach enhances tissue penetration and significantly improves sensitivity to subtle dielectric variations caused by glucose concentration changes. The sensor, optimized for finger placement, operates in the 4–5 GHz range to ensure effective tissue coupling. Experimental validation using multi-layer tissue-mimicking phantoms demonstrated the sensor’s ability to differentiate clinically relevant glucose levels (50–200 mg/dL), achieving a high sensitivity of 0.950 MHz/(mg/dL).

Scientific ReportsVol. 16(1)
Aston University (GB), Vilnius College of Technologies and Design (LT), Center for Physical Sciences and Technology (LT), Sivas State Hospital (TR), İskenderun Technical University (TR), Sivas Bilim ve Teknoloji Üniversitesi (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Openalex Percentile: Top 50%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.